Table Of Contents; Contents; Installation; Prepare The Site - Graco 24E025 Instructions-Parts List Manual

Air controls
Table of Contents

Advertisement

Contents

Contents
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Prepare the Site . . . . . . . . . . . . . . . . . . . . . . . . . 2
Kit Components (page 7) . . . . . . . . . . . . . . . . . . 2
Using the Pipe Port Inserts . . . . . . . . . . . . . . . . . 2
Adding a Lubricator (Accessory) . . . . . . . . . . . . . 3
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Pressure Relief Procedure . . . . . . . . . . . . . . . . . 4
Adjusting the Air Regulator . . . . . . . . . . . . . . . . . 4
Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Air Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Lubricator Service (Accessory) . . . . . . . . . . . . . . 5
Repair Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Air Filter/Regulator . . . . . . . . . . . . . . . . . . . . 6
C11034 Lubricator . . . . . . . . . . . . . . . . . . . . . . . 6
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 14

Installation

Prepare the Site

NOTE: Always use Genuine Graco Parts and Accesso-
ries, available from your Graco distributor. If you supply
your own accessories, be sure they are adequately
sized and pressure rated for your system.
Bring a compressed air supply line from the air com-
pressor to the pump location. Be sure all air hoses are
properly sized and pressure-rated for your system. Use
only electrically conductive hoses. The air hose should
have a 3/4 npsm(m) thread. Before installing any air line
components, blow out the air lines to remove scale and
other debris. Use pipe compound or tape sparingly and
only on male threads.
Install a bleed-type shutoff valve in the air line upstream
from all other air line components, to isolate them for
servicing.
2
Kit Components (page 7)
Use the bleed-type master air valve (3) to relieve air
trapped between it and the pump when the valve is
closed. This helps reduce the risk of serious injury,
including fluid injection and splashing of fluid in the
eyes or on the skin, and injury from moving parts if
you are adjusting or repairing the pump.
Bleed-Type Master Air Valve (3)
Relieve air trapped between it and the air motor when
the valve is closed. Be sure the bleed valve is easily
accessible from the pump, and is located downstream
from the air filter/regulator (1).
Air Filter/Regulator (1)
Controls pump speed and outlet pressure by adjusting
the air pressure to the pump. It also removes harmful
dirt and moisture from the compressed air supply.
Locate the regulator as close as possible to the equip-
ment it serves, but upstream from the bleed-type mas-
ter air valve (3). Install the regulator in the air line so the
air flow is in the direction of the arrow stamped on the
body.

Using the Pipe Port Inserts

To open the pipe port insert (A), remove the insert pin
(S) and pull insert up in direction away from pin hole.
Install new insert and reinsert pin.
A
S
ti1249a
3A0293H

Hide quick links:

Advertisement

Table of Contents
loading