OPTIFLAME ELECTRIC FIREPLACE
OPERATION
WALL MOUNTED CONTROLS
The fireplace can be installed with wall-
mounted controls in addition to the controls
provided. These controls include wall
switches and thermostats.
A. Wall Mounted Thermostats
ALL MODELS WITH REMOTE CONTROL.
When the fireplace is set to Level 2, or Level 3
the wall mounted thermostat will control the
heat output of the unit. When the fireplace is
set to Level 2, or 3 the heater will not activate
until the wall mounted thermostat senses an
ambient temperature lower than the
temperature to which it is set.
B. Wall Mounted Switches
ALL MODELS WITHOUT REMOTE
CONTROL ONLY.
This model may be installed such that a wall-
mounted switch activates the flame effect and
a wall mounted thermostat activates the
heater.
RESETTING THE TEMPERATURE
CUTOUT SWITCH
The heater on this fireplace is protected with a
safety device to prevent overheating. Should
the heater overheat, an automatic cut out will
turn the heater off and it will not come back on
without being reset. It can be reset by
switching the Main Power switch (FIGURE 3)
to OFF and waiting 5 minutes before switching
it to ON.
The remote control will need to be re-initialized.