Operating Method - LG MULTI F A2UW16GFA0 Engineering Product Data Book

Hide thumbs Also See for MULTI F A2UW16GFA0:
Table of Contents

Advertisement

3. Installation of outdoor unit
3.9.7 PCB Display(16/21k Model Only)
It is useful to check the cycle data without LGMV.

Operating Method

Whenever you push the Tact Switch, the cycle information will be shown as below.
h After 1page is displayed, subsequently 2page is displayed.
Tact S/W
14/16k
18/21k
-
1 time
-
2 time
1 time
3 time
Discharge Temp.
2 time
4 time
Cond Out Temp.
3 time
5 time
Suction Temp.
4 time
6 time
ODU Air Temp.
5 time
7 time
6 time
8 time
7 time
9 time
8 time
10 time
DC Link Voltage
WARNING
When you push the Tact Switch, use the material non-conducting electricity.
Item
Example
Low Pressure
890kpa
Hi Pressure
2900kpa
Current
Voltage
Comp Hz
TACT-SW1
Display
1page
'LP'
'HP'
85°C
'DS'
-10°C
'CS'
-10°C
'SS'
-10°C
'AS'
15A
'A'
230V
'V'
100Hz
'F'
230V
'dc'
2page
' 89'
'290'
' 85'
'-10'
'-10'
'-10'
' 15'
'230'
'100'
'230'
Heat pump
60Hz/R410A
_ 58

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multi f a3uw21gfa0Multi f a5uw30gfa0Multi f a5uw40gfa0

Table of Contents