Download Print this page

Extron electronics VNM Enterprise Controller Setup Manual page 2

Replacement compact flash card
Hide thumbs Also See for VNM Enterprise Controller:

Advertisement

VNM Enterprise Controller Compact Flash Card • Setup Guide (Cont'd)
Configuring the Enterprise Controller
Use the following procedures to configure the new CF card.
Setting the Serial Number
If they are not already connected, connect a mouse, keyboard, and monitor to the Enterprise Controller.
1.
Apply power and switch on the Enterprise Controller.
2.
When fully booted, log on with the username of root and the password of Extron2010.
3.
At the prompt [root@singleton ~]#
4.
Type cd scripts
Press <Enter>
At the prompt [root@singleton scripts]#
5.
type ./set_serial.sh xxxxxx
where xxxxxx is the serial number of the Enterprise Controller, which was saved in step 7 on page 1.
Press <Enter>
6.
A script runs, which enters the serial number into the Enterprise Controller.
At the prompt [root@singleton ~]#
7.
type reboot
Press <Enter>
The Enterprise Controller reboots.
License Configuration
Once the Enterprise Controller has rebooted and is connected to the control PC via the network, open the PC web
1.
browser, enter the IP address of the Enterprise Controller into the browser address bar and press <Enter>.
NOTES: • By default, the new card has an IP address of 192.168.254.254.
• The control PC requires an IP address within the range of 192.168.254.xxx to connect to the Enterprise
Controller.
In the Username field of the login page, enter admin. By default, nothing is required for the Password field. Click
2.
Login.
Select the Configuration tab.
3.
Under System Properties, select System Config from the menu on the left of the screen.
4.
In the controllers box, click the Add button. Enter the IP address of this controller. Click OK to save. When the dialog box
5.
closes, click Apply Changes to save the settings.
In the Controllers box, select the IP address of this controller. Click on the License button.
6.
Enter the information gathered in step 7 on page 1.
7.
CAUTION:
NOTE:
When updating the license information, there is no feedback to say that the settings have been accepted.
To check the license data, reboot the Enterprise Controller, reconnect to the Enterprise Controller using the control PC
8.
browser, and view the information contained in the License Management dialogue.
The information in the License Management dialogue takes several seconds to appear after reboot has completed. If
the data does not appear, close the dialogue box, wait for ten seconds and retry. If the data is still not present, enter
the serial number and license data again.
The Enterprise Controller is now ready to be configured for the VN-Matrix system. For precise details of the
configuration, refer to the user guide (available at www.extron.com).
Extron USA - West
Extron USA - East
Headquarters
+800.633.9876
+800.633.9876
Inside USA/Canada Only
Inside USA/Canada Only
+1.714.491.1500
+1.919.863.1794
+1.714.491.1517 FAX
+1.919.863.1797 FAX
2
The licensing information must be entered accurately. Any errors in copying the data to the new
installation will result in a non-functional unit.
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
©
2011 Extron Electronics All rights reserved.
Extron Asia
Extron Japan
+81.3.3511.7655
+800.7339.8766
+81.3.3511.7656 FAX
Inside Asia Only
+65.6383.4400
+65.6383.4664 FAX
www.extron.com
Extron China
Extron Middle East
+971.4.2991800
+400.883.1568
+971.4.2991880 FAX
Inside China Only
+86.21.3760.1568
68-2124-50
+86.21.3760.1566 FAX
Rev. A 05 11

Advertisement

loading