This setup guide describes how to replace an existing VNM Enterprise Controller Compact Flash (CF) card. When the card is
replaced, the Enterprise Controller will be returned to the default configuration and can then be configured for the system
in which it will be used.
The replacement CF card is configured with the following Extron factory default settings:
IP address: 192.168.254.254
z
NOTE:
This procedure assumes the user knows the current password and IP address for the controller.
Saving the Enterprise Controller Configuration Settings
Before replacing the Enterprise Controller CF card, follow the steps below to collect information about the current system
configuration. The information can be copied and pasted into a text program (for example, Notepad).
CAUTION:
All of the information that is saved in this section must be accurately saved so that it can be re-entered into
the Enterprise Controller after installing the compact flash card.
Ensure the Enterprise Controller has a CF card installed.
1.
Switch on the Enterprise Controller and connect it to a control PC,
2.
via the network.
Open the control PC web browser program.
3.
Enter the IP address of the Enterprise Controller into the browser
4.
address bar and press <Enter>.
At the login page, enter the username and password (see the
5.
figure to the right). Click Login.
NOTE:
The default username is admin. By default, no password is required. Be aware that the password may have
changed. Entries are case sensitive.
The Enterprise Controller web page opens.
Select the Configuration tab, then System Config from the
6.
menu on the left (see the figure to the right).
In the Controllers box:
7.
Click on the IP address of this Enterprise Controller.
z
Click on the License button. From the Controller License
z
Management window, note the Options, Checksum, and
Serial Number values.
CAUTION:
The licensing information must be noted
accurately. Copying incorrect data to the new
installation will result in a non-functional unit.
Installing the Compact Flash Card
NOTE:
The replacement card must be programmed with the correct operating system and Enterprise Controller
application files.
Switch off the Enterprise Controller and remove the front cover plate from the CF drive.
1.
Eject the CF card from the CF drive and insert the replacement CF card.
2.
Replace the CF drive cover.
3.
Username: admin
z
Product Category
By default, no password is assigned.
z
1

Advertisement

loading

Summary of Contents for Extron electronics VNM Enterprise Controller

  • Page 1 Replacement Compact Flash Card • Setup Guide This setup guide describes how to replace an existing VNM Enterprise Controller Compact Flash (CF) card. When the card is replaced, the Enterprise Controller will be returned to the default configuration and can then be configured for the system in which it will be used.
  • Page 2 VNM Enterprise Controller Compact Flash Card • Setup Guide (Cont’d) Configuring the Enterprise Controller Use the following procedures to configure the new CF card. Setting the Serial Number If they are not already connected, connect a mouse, keyboard, and monitor to the Enterprise Controller.