ITEM DESCRIPTION
f.1
POWER SWITCH
(FILTER-OFF-FRYER)
v.2
VENTILATOR POWER LIGHT
(green)
v.3
CHECK FILTERS LIGHT
(amber)
v.4
REPLACE FILTERS LIGHT
(amber)
v.5
SERVICE REQUIRED LIGHT
(red)
v.6
VENTILATOR BLOWER
v.7
FUSIBLE LINK LOCATION
v.8
FIRE SUPPRESSION
NOZZLE(S)
f.9
FILTER PUMP MOTOR
OVERLOAD RESET
v.10 VENTILATOR EXHAUST
COLLAR
v.11
CHARCOAL FILTER
v.12
HEPA AIR FILTER
v.13
GREASE BAFFLE
v.14 ANSUL® SYSTEM STATUS
INDICATOR
v.15 ACCESS TO AUTOLIFT
MOTOR
v.16 MANUAL PULL STATION
v.17 GREASE CUP
f.18
DRIP PAN
f.19
STABILIZER
f.20
RIGID (REAR) CASTERS
If a remote pull station is installed, both rear casters must be replaced with fixed legs in order to deter movement of
unit. MOVING AN APPLIANCE EQUIPPED WITH A REMOTE PULL STATION WILL DISCHARGE THE FIRE
f.21
FIXED (FRONT) LEGS
FEATURES & OPERATING CONTROLS (continued)
FUNCTION
FRYER position energizes VENTILATOR POWER LIGHT and BLOWER.
If, within 10 seconds, there is sufficient airflow for proper operation,
POWER LIGHT will remain ON and fryer will operate.
Glows when FRYER POWER SWITCH in pressed to FRYER and adequate
airflow has been proven.
Glows when GREASE BAFFLE and/or HEPA FILTER are not properly
installed. When this light is lit, fryer is disabled.
Glows if either CHARCOAL FILTER or HEPA FILTER are due for
replacement. Fryer will continue to operate, but filters must be changed in
a timely manner before they clog and disable the fryer.
Glows when there is insufficient airflow for proper operation (either
CHARCOAL FILTER or HEPA FILTER, or both, plugged). When this light
is lit, fryer is disabled.
Provides ventilation airflow.
FUSIBLE LINKS provide fire protection by melting at a pre-set temperature
and activating the fire suppression system.
Disperse the fire suppression media.
Provides over-temperature protection for the FILTER PUMP MOTOR.
Reset manually by pressing the red button.
Ventilator discharge. DO NOT BLOCK.
Contains fire damper with pre-installed 285ºF (141ºC) fusible link.
See page 10.
Indicates status of Ansul® fire suppression system
(i.e. COCKED or FIRED).
On fryers with automatic basket lifting device (WVAE-series) allows
servicing of lift mechanism.
Allows manual discharge of fire suppression system. Shown on left side,
may also be mounted on right side. IMPORTANT: PULL STATION must
be field installed by an ANSUL® technician.
Catches drippings from GREASE BAFFLE.
Catches any liquid draining from top of fryer section.
Prevents unit from tipping backwards.
Allows unit to be easily positioned by slightly lifting front of unit.
IMPORTANT
SUPPRESSION SYSTEM.
Allows the unit to be leveled.