TROUBLESHOOTING SUGGESTIONS

PROBLEM
Unit will not operate
(no indicators lights lit)
Unit will not operate
(buzzer sounds)
CHECK FILTER light lit
REPLACE FILTERS light lit
SERVICE REQUIRED light lit
(fryer not operating)
IMPORTANT:
Contact ANSUL® for fire suppression system installation, set-up and service:
Ansul Incorporated
One Station Street
Marinette, WI 54143-2542
IMPORTANT:
Parts used in the Ansul® fire suppression system are not serviceable by the owner/operator.
Procedures for servicing fire suppression equipment are described in:
ANSUL® R-102 SYSTEM DESIGN, INSTALLATION, RECHARGE AND MAINTENANCE MANUAL
(418087, current edition)
NOTE:
ANSUL® Manual 41807 and Wells Bulletin 301646 are intended for use by authorized Ansul® service
personnel only.
POSSIBLE CAUSE
Disconnected from electric power
Fire suppression system not set
HEPA air filter or grease baffle not in position
HEPA air filter and charcoal filters nearing
end of service life
HEPA air filter and charcoal filters plugged
Fire damper in exhaust collar has closed
One or more vacuum sensing lines or ports
plugged
NOTE: If, after 10 seconds, there is insufficient airflow for proper operation, SERVICE REQUIRED
light will illuminate and fryer will be de-energized.
Press FRYER POWER SWITCH to OFF, then back to FRYER to reset system.
1-800-TO-ANSUL (1-800-862-6785)
website http;//www.ansul.com
SUGGESTED REMEDY
Reconnect to electric power
Reset circuit breaker for unit
Contact an authorized Ansul® distributor for repairs
Properly install HEPA filter and grease baffle
Arrange to replace both HEPA and charcoal filters in
a timely manner
Replace both HEPA and charcoal filters
Contact an authorized Wells service agent for
repairs
Contact an authorized Wells service agent for
repairs
NOTE:
FILTERS are the only user serviceable components
in this ventilator hood system. For all problems that
cannot be remedied by servicing the filters, contact:
Fryer or ventilator section - authorized Wells
service agency
Fire suppression system - authorized Ansul®
distributor