Download Print this page

Installing The Sensor - JUKI PS-800 Instruction Manual

Bobbin thread remaining amount detection device
Hide thumbs Also See for PS-800:

Advertisement

3-1. Installing the sensor

❶ ❶
❷❼❽
❷❼❽
❹ ❹
 
 
 
❻ ❻
❷❼❽
❷❼❽
❺ ❺
❻ ❻
❸ ❸
❺ ❺
– 6 –
1) Temporarily secure fixation plate A ❹ , fixation
plate B ❺ and sensor ❶ as illustrated in the
figure.
Secure the aforementioned parts after you
have adjusted sensor. Firmly assemble them
so that they do not rattle.
❷ Sensor fixation screws (2 pieces)
❸ Nut
❻ Plate fixation screws
❼ Sensor fixation plain washer
❽ Sensor fixation spring washer
❹ ❹
Inner hook
2) Detach hook oil supply tube  . Detach fixa-
tion screws  of the oil tank. Secure sensor
fixation plate B ❺ between the oil tank and the
bed. Pass tube  through the hole in the plate
and connect to the oil tank.
3) Secure sensor ❶ while shifting it to the left
side of plate ❹ .
❶ ❶
Left side