Operating temperature: 5dC to 40dC
(When the inner of the unit becomes less than 5dC, the
hard disk portion does not start up because of entering
into warm up mode. The inner of the unit becomes 5dC
or more, the hard disk portions start up automatically.)
Operating humidity:
25% to 80%
(Condensation not allowed)
_20 dC to 60 dC
Storage temperature:
Locations to avoid:
. Areas where the unit will be exposed to direct sunlight
or any other strong lights.
. Areas near heat sources.
. Dusty areas or areas subject to vibration.
. Areas with strong magnetic field.
. Areas with much electrical noise.
. Areas with much static electricity.
. Areas that is impossible to find a specified room for
installation.
(Refer to "1-5. Installation Space")
. Areas windtight
Horizontal condition: Do not slant the front and rear of the
unit more than 30 d.
c
Fix the unit securely to avoid slipping if the unit is not
operated at horizontal place.
1-4. Power Supply

1-4-1. Voltage and Power Requirements

n
Be sure to operate the unit within the range of following
power voltage.
AC 100 to 240 V ± 10%
Power voltage:
Power frequency:
50 Hz or 60 Hz
Power consumption: 285 W (AC100 V IN: 3 A)
Rush current:
Power voltage 100 V IN: 7 A
Power voltage 240 V IN: 7 A
This unit's power line has a switching regulator with the
power factor 98 %.
1-2 (E)
(AC240 V IN: 1.5A)
n
AC power supply is required a capacity which is commen-
surate with rush current.
If the capacity of the AC power supply is not enough, the
breaker of AC power of a supply side may operate or this
unit may not operate normally.

1-4-2. Power Cord

w
Use the specified power cord only when connecting.
Never use a injured power cord.
Power cord for the customer in the U.S.A. and Canada.
1 Power cord (approx. 2.5 m) ! 1-557-377-11
2 Plug holder (brown)
Contact your local Sony Sales Office/Service Center.
1
Power cord for the customer in Europe.
1 Power cord (approx. 2.5 m) ! 1-782-929-11
2 Plug holder (brown)
Contact your local Sony Sales Office/Service Center.
1
If the unit is used in the area except above, contact your
local Sony Sales Office/Service Center.
3-613-640-01
AC inlet
2
3-613-640-01
AC inlet
2