Figure 8: MxC 290 Triple Output Evaluation Board Synchronized to SMPS Wiring Diagram
Warning: Do not "Hot-Plug" the power supply or electronic load.
Recommended start-up procedure:
1) With power supply off, attach power supply wires.
2) With electronic load disabled (monitor mode), attach electronic load wires.
3) Turn on power supply.
4) Enable electronic load with no load current, and then ramp up load current.