Warning: Do not "Hot-Plug" the power supply or electronic load.
Recommended start-up procedure:
5) With power supply off, attach power supply wires.
6) With electronic load disabled (monitor mode), attach electronic load wires.
7) Turn on power supply.
8) Enable electronic load with no load current, and then ramp up load current.
Table 9: MxC 284 4x Voltage Boost + LED EVB Connector – J1
Pin No.
Name
1
VIN
2
GND
Note:
3) Due to board's small size, thermal dissipation is limited and may exceed the over-
temperature shutdown threshold.
4) The MxC 284 can be powered from 6V to 12V delivering 24V to 48V, respectively to the
current source regulator.
5) Higher output current is possible with additional fly and hold capacitance.
MxC® 200 PoL EVB Manual
Description
+9VDC Input Power Pin
Power GND Pin
Helix Semiconductors, 2019 All Rights Reserved