Step 13
Connect filled LP tank
WARNING: Make sure that the LP tank valve is
closed. Close by turning clockwise.
Hook the LP tank onto the fuel scale. Loosen the tank
lock wing nut. Swing the tank lock down. Tighten the
wing nut. Figure 18.
Figure 18
Remove the tape from the hose and regulator.
Route the hose so it will not interfere with the scale
indicator rod.
The hose and regulator are connected in the following
manner:
Slide back the collar of the quick disconnect on the tank
valve. Push the male fitting of the regulator into the quick
disconnect, and maintain pressure. Slide the collar
closed. Figure 19 (a). Figure 19 (b) shows the quick
Tank lock wing
disconnect engaged and various components of the tank
nut
and regulator. Regulator vent hole should be at 3, 6, or 9
o'clock. It should not be pointed up. Figure 19 (c).
8
(a)
Male
fitting
Hose
Tank valve
Regulator
Regulator
vent
Quick disconnect
engaged
(c)
Figure 19
Collar
(b)
Valve handwheel
close clockwise
Pressure
relief valve
Tank
Turn so regulator vent
does not collect water