S Series - Suburban DynaPack S Series Architects And Engineers' Manual

Vertical packaged air conditioner featuring gas heat/electric cooling designed to serve multi-family applications
Hide thumbs Also See for DynaPack S Series:
Table of Contents

Advertisement

S SERIES

DUCT WORK
The duct work for the dwelling should be designed for the lowest possible
static pressure to reduce energy usage and noise.
cfm delivery of the units on each of the indoor blower speeds.
recommended heating and cooling speeds with its approximate cfm delivery.
Use both tables to properly design the duct system for both heating and
cooling cfm.
MODEL NUMBER Blower Speed 0.10" wc 0.15" wc 0.20" wc 0.25" wc 0.30" wc 0.40" wc 0.50" wc 0.60" wc 0.70" wc 0.80" wc
LO
MED LO
DYPA12AC3A
MED
MED HI
LO
MED LO
DYPA18AC3A
MED
MED HI
LO
MED LO
MED
DYPA24AC3A
MED HI
LO
MED LO
MED
DYPA30AC3A
MED HI
Recommended
MODEL NUMBER
Heating Speed
DYPA12AC3A036
DYPA12AC3A048
DYPA18AC3A036
DYPA18AC3A048
DYPA18AC3A060
MEDIUM HIGH
DYPA24AC3A036
DYPA24AC3A048
MEDIUM HIGH
DYPA24AC3A060
MEDIUM HIGH
DYPA30AC3A036
DYPA30AC3A048
MEDIUM HIGH
DYPA30AC3A060
MEDIUM HIGH
CONDENSATE DRAIN
The DynaPack unit and wall sleeve each have their own drain. The unit drain is
for the condensate developed by the evaporator coil. It needs to be trapped and
routed to the building drain system. Use 3/4" pvc pipe and fittings (field
supplied).
The wall sleeve is equipped with a drain pan that collects rain water entering
the wall sleeve and the unit condenser coil area. At the time of installation of
the wall sleeve, this drain can be directed directly outside or turned inside and
routed to the building drain system. If the wall sleeve drain is routed to the
building sewer system then it must be trapped to prevent sewer gasses
from escaping.
S SERIES INDOOR CFM vs STATIC PRESSURE (Dry coil + no air filter)
497
473
577
562
757
748
937
920
HI
1060
1050
512
491
596
568
773
761
972
955
HI
1108
1091
504
483
588
560
765
753
964
947
HI
1100
1083
490
465
570
540
768
755
934
922
HI
1064
1046
Approx.
CFM
MEDIUM
700
MEDIUM
700
MEDIUM
700
MEDIUM
700
900
MEDIUM
700
900
900
MEDIUM
700
900
900
TABLE 5
lists the approximate
Table 4
lists the
Table 5
448
424
400
547
522
497
739
716
692
905
888
872
1042
1015
977
469
428
387
540
522
504
748
730
711
938
927
915
1074
1057
1039
461
420
379
532
514
496
740
722
703
930
919
907
1066
1049
1031
440
415
385
520
500
476
741
732
704
913
895
873
1017
1009
995
TABLE 4
Approx.
Recommended
Temp Rise ºF
Cooling Speed
38
LOW
50
LOW
38
MEDIUM LOW
50
MEDIUM LOW
50
MEDIUM LOW
38
MEDIUM
40
MEDIUM
50
MEDIUM
38
MEDIUM HIGH
40
MEDIUM HIGH
50
MEDIUM HIGH
21
348
296
247
458
415
357
670
635
586
852
827
790
927
876
824
320
285
250
447
415
381
675
640
622
874
850
825
1002
970
917
312
252
207
439
377
320
667
622
572
866
828
782
994
962
922
310
225
170
415
365
310
666
621
580
835
800
760
965
935
900
Approx.
CFM
400
400
550
550
550
700
700
700
900
900
900
Follow local codes and standards
when designing duct runs to deliver
the required airflow. Minimize noise
and excessive pressure drops caused
by duct aspect ratio changes,
bends, dampers and outlet grilles in
duct runs.
(continued on next page)
Suburban DynaPack A&E Manual 07/2019 Rev.6
212
160
317
281
558
521
728
677
758
700
213
179
324
291
586
550
796
766
868
796
N/R
N/R
262
202
532
482
757
702
882
827
N/R
N/R
250
205
535
500
730
690
875
828
NOTE