Fault Messages And Signal Tones - Dometic 10 Series Operating Manual

Absorber refrigerator
Hide thumbs Also See for 10 Series:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting
Fault
The refrigerator is not
cooling adequately.
7.1

Fault messages and signal tones

All faults are indicated by a warning symbol, a fault ID and a beep. The beeping lasts
for 2 minutes and is repeated every 30 minutes until the error has been rectified.
If multiple faults occur, the display shows the most recent fault. The underlying faults
are displayed after the last fault has been confirmed.
RML10.4T: Faults are indicated by a fault code with a warning symbol (
middle of the TFT display.
RML10.4 and RML10.4S: In the event of a fault, the LED warning symbol (
display lights up continuously and the LEDs flash according to the fault.
34
Possible cause
The ventilation around the cool-
ing unit is not sufficient.
The evaporator is iced up.
The temperature is set too high.
The ambient temperature is too
high.
Too much food was placed in the
refrigerator at the same time.
Too much warm food was placed
in the refrigerator at the same
time.
The refrigerator has not been
operating for very long.
RML10.4, RML10.4S, RML10.4T
Suggested remedy
Check that the ventilation grille is not
obstructed.
Check whether the refrigerator door
closes properly. Make sure that the
refrigerator seal fits correctly and is not
damaged. Defrost the refrigerator.
Set a lower temperature.
Remove the ventilation grille for a
while so that warm air can escape
quicker.
Remove some of the food.
Remove the warm food and leave it to
cool down before putting it in again.
Check the temperature again after four
or five hours.
) in the
in the
)
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rml10.4Rml10.4sRml10.4t

Table of Contents