Group: event_i<0~2>
PARAMETER
name
enable
priority
delay
trigger
di
mdwin
inter
VIVOTEK - A Leading Provider of Multimedia Communication Solutions
VALUE
SECURITY
(get/set)
string[40]
6/6
0, 1
6/6
0, 1, 2
6/6
1~999
6/6
boot,
6/6
di,
motion,
seq,
<integer>
6/6
<integer>
6/6
1~999
6/6
DESCRIPTION
The identification of this entry
To enable or disable this event.
Indicate the priority of this event.
"0" indicates low priority.
"1" indicates normal priority.
"2" indicates high priority.
Delay seconds before detect next event.
Indicate the trigger condition.
"boot" indicates system boot.
"di" indicates digital input.
"motion" indicates video motion detection.
"seq" indicates periodic condition.
Indicate which di detected.
This field is required when trigger condition
is "di".
One bit represents one digital input. The LSB
indicates DI 0.
Indicate which motion detection windows
detected.
This field is required when trigger condition
is "md".
One bit represents one window.
The LSB indicates the 1
For example, to detect the 1
windows, set mdwin as 5.
Interval of period snapshot in minute.
This field is used when trigger condition is
"seq".
st
window.
st
rd
and 3