Sections [20-23] Wireless & Miscellaneous Reporting Types
By programming the Reporting Types sections, you can add additional information to each
transmission.
For example, you can program the reporting code for zone 1 as 01 and the reporting type for zone 1
as 00, to indicate that zone 1 is a fire zone. Refer to the DVACS Reporting Type tables on pages 24-
27.
• To have the PC5720 transmit a pre-programmed code from the internal table, leave the
programming at the default value FF. Default reporting types are listed in the Appendix A.
• To have the PC5720 transmit a different code, program a value from 00-7F.
NOTE: Do not program values above 7F.
Sections [36-39] Zone Definitions
Make sure that the zone definitions match those programmed in the control panel.
Section [40]
DVACS ID Code
Program the DVACS ID code in this section. This code identifies a PC5720 module on a DVACS
subset, specifying which poll from a F2 node the module will respond to. Valid entries are 01 - F0.
Section [41]
All Call Select
Use this section to program which all call response the PC5720 will have. The options are:
(00) no response on any all call
(01) response on all call #1 only
(02) response on all call #2 only
(03) response on both all calls
(04) modules with odd-numbered ID codes (see section 40) respond to All Call #1. Modules with
even-numbered ID codes respond to All Call #2. (E.g. a module withID code 03 will respond to
All Call #1. A module with ID code 04 will respond to All Call #2.)
Section [42]
Miscellaneous (Transmission) Options
Option 1: Turn this option ON to have the PC5720 send alarms during an all call. Turn this option
OFF to have the PC5720 send alarms and restorals during an all call.
Option 2: Turn this option ON to have the PC5720 report which zones have been bypassed. Turn
this option OFF for prevent the PC5720 from reporting which zones have been bypassed.
Option 3: Turn this option ON to have the PC5720 report openings and closings. Turn this option
OFF to to prevent the PC5720 from reporting openings and closings.
Sections [43-68] Reporting Codes
Program the DVACS reporting codes in these sections (see DVACS Transmission Table for
Transmission Codes):
• To have the PC5720 transmit a pre-programmed code from the internal table, leave the
programming at the default value FF. Default reporting codes are listed in the Appendices B.
• To prevent the PC5720 from reporting an event, program the code as 00.
• To have the PC5720 transmit a different code, program a value from 01-FE.