Siemens RUGGEDCOM RX1501 Installation Manual page 32

Hide thumbs Also See for RUGGEDCOM RX1501:
Table of Contents

Advertisement

>Configuration hazard – risk of data corruption/loss
The following will void the warranty and potentially result in configuration data cor-
ruption/loss:
Inserting the CF card
To insert the CF card into the device, do the following:
IMPORTANT
The device should only be powered on when the CF card is present.
1.
2.
3.
4.
RUGGEDCOM RX1501
Installation Manual, 05/2020, C79000-G8976-1054-17
The CF card is deemed defective or corrupt
The device is rendered non-functional due to a serious configuration error, data
corruption, or hardware fault
NOTICE
Using a CF card not approved by Siemens for use with this device
Removing the CF card in any scenario other than those described in this section
Make sure the device is powered down.
Remove the CF card access panel.
Insert the CF card into the slot until it is fully seated.
1
2
CompactFlash Card
1
Access Panel
2
Figure 3.3
Inserting the CF Card
Secure the CF card access panel to the chassis.
Device Management
3.3 Accessing the CompactFlash Card
23