PH Gas Logs
Handle the gas log burner assembly by
the burner only. Do not pick the unit up
by the burners or grate (not attached to
frame).
Gloves are recommended when handling
ceramic fiber logs to prevent skin irritation
from loose fibers. Logs are fragile —
handle with care.
MAKE SURE YOU HAVE RECEIVED ALL PARTS:
Check your packing list to verify that all listed parts have
been received. You should have the following:
Unvented gas log burner assembly
Plastic bag containing crushed volcanic rock
Installation/operating instructions
Two (2) anchoring screws
Grate
Ceramic fiber or refractory cement logs
The millivolt controlled version of this heater is the only
style designed to be operated with optional devices for
ON/OFF functions. The following options may be used
with the millivolt controlled heater. These options are not
packaged with the log set.
Hand held Remote with receiver
Wall thermostat with 15' wire
Wall switch with 15' wire
Hand held Thermostat Remote with receiver
Monessen • PH18/24 Installation/Owner's Manual • 65D2035 • Rev G • 03/2020
6
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance. Do not
attempt to install any part of the appliance unless you
have all parts in good condition.
WHAT YOU WILL NEED FOR INSTALLA-
TION:
You should have the following items available before pro-
ceeding with installation:
External regulator (for propane/LPG and 1/2 lb.
natural gas systems only)
Piping which complies with local codes
Sediment trap (recommended)
Screwdriver
Tee joint.
Pipe sealant approved for use with propane/LPG
(Resistant to sulfur compounds)
Drill with 5/32 bit
Pipe wrench or appropriate size crescent wrench
set
Manual shutoff valve
If the area in which the heater may be
operated does not meet the required volume
for indoor combustion air, combustion and
ventilation air shall be provided by one
of the methods described in the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, the
International Fuel Gas Code or applicable
local codes.