Operation & Troubleshooting - Delta 72045T Quick Start Manual

Hide thumbs Also See for 72045T:
Table of Contents

Advertisement

1
Troubleshooting:
1
20
Operation & Low battery:
Wait 15 seconds after power is applied for unit
to power up. It may take 1 tap to initialize your
dispenser depending on the position of your spout
when power was applied. When replacing your
spout or rotating off-on, wait until the lights turn
off before operation. Note: To initially prime your
dispenser it may take several operations depending
on the thickness of your soap. When the dispenser
is operating normally the LED (1) will illuminate
BLUE. When your batteries are low the LED will
flash RED during operation as a reminder to replace
your batteries. If the dispenser does not dispense
soap and the red light is flashing, your batteries
are no longer able to operate the pump. If the
dispenser does not dispense soap and your LED is
BLUE, you may need to refill your dispenser. Note:
If you choose to clean the soap bottle, ensure the
electronics do not get wet.
.
Red Light with new batteries.
May have one or more batteries reversed.
.
Pump performance poor.
Soap or lotion may be too thick. May need to
increase run time (page 5). Or, add a small
amount of water to soap.
.
No Activation / No Light
Spout may not be secure on base (gap between
spout and base). Spout may be rotated too far
from center of base and inadvertently turned unit
off. Remove and replace spout in center position.
If light is still not on, remove battery cap and
reinstall to reset unit.
.
Pump turns on when grabbing to rotate off or
when working in sink area.
This may occur if you approach the unit at a slow
rate. If unit is in proximity mode, it will sense your
approach and turn on before it can process the
grab. Approach at faster rate. If desired, hands-
free can be disabled to prevent this as well.
.
Poor or inadvertent touch or proximity
performance.
Excess amounts of water and / or soap on base
and contact clip. Clean and dry base to improve
performance.
Hands/fingers not close enough to spout to
activate proximity feature.