• Because your air conditioner contains R-32
refrigerant, make sure that it is installed, operated,
and stored it in a room whose floor area is larger
than the minimum required floor area specified in
the following table:
Wall-mounted type
m (kg)
≤ 1.842
1.843
1.9
2.0
2.2
2.4
2.6
2.8
3.0
– m : Total refrigerant charge in the system
– A : Minimum required floor area
• IMPORTANT: it's mandatory to consider either the
table above or taking into consideration the local
law regarding the minimum living space of the
premises.
• Minimum installation height of indoor unit is 0.6 m
for floor mounted, 1.8 m for wall, 2.2 m for ceiling.
Installation of the outdoor unit
• While in installation or relocation of the product, do
not mix the refrigerant with other gases including
air or unspecified refrigerant. Failure to do so may
cause pressure increase to result in rupture or
injury.
• Do not cut or burn the refrigerant container or
pipings.
• Use clean parts such as manifold gauge, vacuum
pump, and charging hose for the refrigerant.
• Installation must be carried out by qualified
personnel for handling the refrigerant. Additionally,
reference the regulations and laws.
• Be careful not to let foreign substances (lubricating
oil, refrigerant, water, etc.) enter the pipings. The
application of oil or refrigerant deteriorates the
pipings to result in drain leakage. For storage,
securely seal their openings.
• When mechanical ventilation is required, ventilation
openings shall be kept clear of obstruction.
• For disposal of the product, follow the local laws
and regulations.
• Do not work in a confined place.
• The work area shall be blocked.
• The refrigerant pipings shall be installed in the
• The following checks shall be performed for
A (m
)
2
No requirement
4.45
4.58
4.83
5.31
5.79
6.39
• Upon leakage of the refrigerant, ventilate the room.
7.41
8.51
• Make sure that the work area is safe from
• To purge air in the refrigerant, be sure to use a
• Note that the refrigerant has no odour.
• The units are not explosion proof so they must be
• This product contains fluorinated gases that
• Because the working pressure for R-32 is 1.6 times
• The models that use the refrigerant R-32 have a
• Servicing shall be performed as recommended by
• For servicing the units containing flammable
• Servicing shall be performed following the
• Do not install where there is a risk of combustible
position where there are no substances that may
result in corrosion.
installation:
– The charging amount depends on the room
size.
– The ventilation devices and outlets are
operating normally and are not obstructed.
– Markings and signs on the equipment shall be
visible and legible.
When the leaked refrigerant is exposed to flame, it
may cause generation of toxic gases.
flammable substances.
vacuum pump.
installed with no risk of explosion.
contribute to global greenhouse effect. Accordingly,
do not vent gases into the atmosphere.
higher than that for R-22, use exclusive pipings
and tools specified. In case of replacing an R-22
model with an R-32 model, be sure to replace the
conventional pipings and flare nuts with exclusive
ones.
different thread diameter for the charging port
to prevent charging failure. Therefore, check its
diameter (1/2 inch) in advance.
the manufacturer. In case other skilled persons are
joined for servicing, it shall be carried out under
supervision of the person who is competent in
handling flammable refrigerants.
refrigerants, safety checks are required to minimise
the risk of ignition.
controlled procedure to minimize the risk of
flammable refrigerant or gases.
gas leakage.