disassembled in conditions of complete safety either
for people or things. For this reason, where it is not
observed as indicated into the Installation Manual,
the cost necessary to reach and repair the unit (in
safety, as required by current regulations in force)
with slings, trucks, scaffolding or any other means of
elevation won't be considered in-warranty and will
be charged to end user.
• The outdoor unit shall be installed in an open space
that is always ventilated.
• The local gas regulations shall be observed.
• To handle, purge, and dispose the refrigerant, or
break into the refrigerant circuit, the worker should
have a certificate from an industry-accredited
authority.
• Do not install the indoor unit in the following areas:
– Area filled with minerals, splashed oil, or steam.
It will deteriorate plastic parts, causing failure or
leakage.
– Area that is close to heat sources.
– Area that produces substances such as sulfuric
gas, chlorine gas, acid, and alkali. It may cause
corrosion of the pipings and brazed joints.
– Area that can cause leakage of combustible gas
and suspension of carbon fibers, flammable dust,
or volatile flammables.
– Area where refrigerant leaks and settles.
– Area where animals may urinate on the product.
Ammonia may be generated.
• Do not use the indoor unit for preservation of food
items, plants, equipment, and art works. This may
cause deterioration of their quality.
• Do not install the indoor unit if it has any drainage
problem.
Installation Guide at the seashore
• Make sure to follow below guides when installing at
the seashore.
1. Do not install the product in a place where it is
directly exposed to sea water and sea breeze.
– Make sure to install the product behind a
structure (such as building) that can block see
breeze.
– Even when it is inevitable to install the product
in seashore, make sure that product is not
directly exposed to sea breeze by installing a
protection wall.
2. Consider that the salinity particles clinging to the
external panels should be sufficiently washed out.
4 English
3. Because the residual water at the bottom of the
outdoor unit significantly promotes corrosion,
make sure that the slope does not disturb drainage.
– Keep the floor level so that rain does not
accumulate.
– Be careful not to block the drain hole due to
foreign substance
4. When product is installed in seashore, periodically
clean it with water to remove attached salinity.
5. Make sure to install the product in a place that
provides smooth water drainage. Especially, ensure
that the base part has good drainage.
6. If the product is damaged during the installation or
maintenance, make sure to repair it.
7. Check the condition of the product periodically.
– Check the installation site every 3 months and
perform anti-corrosion treatment such as R-Pro
supplied by SAMSUNG (Code : MOK-220SA) or
commercial water repellent grease and wax, etc.,
based on the product condition.
– When the product is to be shut down for a long
period of time, such as off-peak hours, take
appropriate measures like covering the product.
8. If the product installed within 500m of seashore,
special anti-corrosion treatment is required.
※ P lease contact your local SAMSUNG
representative for further details.
Outdoor
unit
Outdoor
unit
Sea breeze
Sea
Outdoor
unit
Sea breeze
Sea
• Protection wall should be constructed with a solid
material that can block the sea breeze and the
height and width of the wall should be 1.5 times
larger than the size of the outdoor unit. (You must
secure more than 700mm of space between
the protection wall and the outdoor unit for air
circulation.)
• For the multi system, this indoor unit can be
conncected to an R-32 or R-410A outdoor unit.
Check the type of refrigerant in the outdoor unit.
Outdoor
unit
Protection wall
Sea breeze
Outdoor unit
Sea