Distance from the Center of the Flue Collar to the Wall
The information on this page is helpful in planning stove placement, particularly in those installations with
chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must
adhere to the guidelines in the clearance chart on page 12.
Note that rear dimensions differ for installations with 6" or 8" chimney connectors.
Unprotected Surfaces
Parallel Installations
Side (A)
Rear (B)
39 " (1003mm)
6" chimney:
27" (685mm)
8" chimney:
28" (710mm)
Side (A)
Rear (B)
39 " (1003mm)
6" chimney:
17" (685mm)
8" chimney:
18" (710mm)
Defiant With Rear Heat Shield and Double-wall Connector:
Side (A)
Rear (B)
39 " (1003mm)
6" chimney:
17" (685mm)
8" chimney:
18" (710mm)
A
*
* This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this
page: 34" (865mm) in the United States and 36" (914mm) in Canada.
Defiant With Rear Heat Shield only
Corner
Installations
Corner (C)
28" (710mm)
Defiant With Rear Heat Shield and Shielded Connector:
Corner (C)
28" (710mm)
Corner (C)
28" (710mm)
B
C
*
Vermont Castings Defiant
Protected Surfaces
Parallel Installations
Side (D)
Rear (E)
29 " (710mm)
6" chimney:
21" (535mm)
8" chimney:
22" (560mm)
Side (D)
Rear (E)
29 " (710mm)
6" chimney:
17" (535mm)
8" chimney:
18" (560mm)
Side (D)
Rear (E)
29 " (710mm)
6" chimney:
15" (535mm)
8" chimney:
16" (560mm)
D
Corner
Installations
Corner (F)
25" (635mm)
Corner (F)
25" (635mm)
Corner (F)
25" (635mm)
F
E
15