Vermont Castings 968 Installation And Operating Manual page 14

Vermont 1910, 0968 woodburning stove operating manual
Table of Contents

Advertisement

Vermont Castings Defiant
48"
(1220mm)
48"
(1220mm)
IN TR
E PID
II
Fig. 12 Parallel installation, vertical chimney connector, two
wall shields. Reduced clearances for both rear and side walls.
Wall shields may meet at corner if desired. Shielding for
connector is centered behind connector.
48"
(1220mm)
48"
(1220mm)
D E
FIA NT
Fig. 13 Parallel installation with rear wall pass-through, two
wall shields. Reduced clearances to both rear and side walls.
Wall shields may meet at corner if desired. Wall pass-through
must comply with codes.
Refer to "Special Installations."
14
48"
(1220mm)
48"
(1220mm)
ST497
48"
(1220mm)
ST498
48"
(1220mm)
48"
(1220mm)
Fig. 14 Corner installation, vertical chimney connector, two
wall shields. Reduced side clearances. Wall shield MUST
meet at corner.
Stove Heat Shields
The Vermont Castings Defiant Rear Heat Shield,
shown below, is one way to reduce the clearance to
the rear wall. The rear heat shield can be installed in
any setting. However, since the chimney connector
also radiates heat toward the wall, you should use a
chimney connector shield whenever you use the rear
heat shield.
Clearance reductions with the rear heat shield
apply only to the wall to the rear in parallel installations.
Neither the side clearance requirement nor the clear-
ance requirement in corner installations may be re-
duced.
Fig. 15 The rear heat shield installed on the Defiant Stove.
48"
(1220mm)
48"
(1220mm)
ST499
N T
F I A
D E
ST500