Junction Box
Fig. 47 Slide the elevated base platform into the cabinet until
it contacts the back panel.
FP1126
Optional Blower
Flange attaches
to cabinet rear
wall
Convectiion
Blower Power
Cord
Fig. 48 The cabinet convection blower in place behind the
base.
FP1126
blower housing
5/24/01 djt
2000941
Optional
Blower
Elevated Base
FP1126
Cabinet Convection
Blower Housing
Flange
attaches to
base
Elevated Base
FP1127
WinterWarm Fireplace Insert or System
Use drywall screws to fasten the wall covering to the
metal standoff and drywall stops at the cabinet. Drill
pilot holes through the wall covering material and one
thickness of the sheet metal with a #40 (.098") drill bit.
Tape and fill holes and/or seams and decorate your
chase wall at this time.
11. Install the vent grilles. Position the cast grilles over
the duct box openings, and mark for the four screw
holes in each. Using a 5/32" (4mm) bit, drill through the
drywall and duct box flanges, and install the grilles with
the Phillips flat head black oxide screws.
Once the vent grilles have been installed, you are ready
to complete the installation by installing the fire cham-
ber and the front.