Use The Right Adhesives; Top View Of Plaster Flush-Finished Trim; Top View Of Tile And Wooden (Combustible) Trim Installed Over Backer Board - Vermont Castings Winter warm 2100 Installation And Operating Manual

Fireplace insert or system
Table of Contents

Advertisement

Finish Coat
Backer Board
or Metal Lath
Fig. 37 Top view of plaster flush-finished trim.
mented directly to the trim panels, or over noncom-
bustible backing to shim it out relative to the finished
wall surface. Be sure the height of the side pieces
is between 29" (740 mm) and 33¹⁄₄" (845 mm), and
that the thickness of backing, adhesive, and stone
combined is not more than 13/16" (20 mm).
Tile. There are many tile options from which to
choose. Here is one method of determining a satis-
factory arrangement:
Total thickness less
than 13/16" (20mm)
Observe
Combustible
Limits
Fig. 38 Top view of stone facing material and wooden (com-
bustible) trim cemented directly to a noncombustible backing.
The trim must protrude no more than 2" (51mm).
1. Draw the maximum and minimum fireplace open-
ing dimensions on a large sheet of cardboard.
2. Place it on the floor and experiment with laying
the tiles around the opening, varying within the
limits to determine the best arrangement.
3. Trace and cut out a silhouette of the insert. Lay it
over the tiles to show how the insert will cover the
tiles when it is installed.
4. On another large piece of cardboard, cut an
opening to represent the limits for combustible
material, and position that on top of the tile lay-
out. Keep in mind that while combustible material
must not be brought inside the combustible limits,
2000941
FP1114
FP1114
WW
plaster trim
4/5/01 djt
FP1114
WW
plaster trim
4/5/01 djt
it is entirely permissible to extend noncombustible
facing materials beyond those limits to achieve a
particular decorative effect.
5. Despite the most careful planning and the latitude
provided by the maximum and minimum opening
dimensions, it still may be necessary to cut some
tiles to achieve a balanced appearance. Your tile
supplier or local tool rental outlet should be able
to supply the necessary equipment and explain
how to use it properly.
Consult your Vermont Castings dealer for advice and
suggestions for this process.
Observe
combustible
limits 2" (51mm)
maximum
Fig. 39 Top view of tile and wooden (combustible) trim in-
stalled over backer board.

Use the Right Adhesives

The adhesive must be suitable to the chosen mate-
rial and have a temperature rating of at least 400°F
(204°C). High temperature silicone is an example.
Maintain a Safe Clearance to the Mantel
The clearance to the mantel and/or top trim must be at
FP1115
least 43" (1090mm), measured from the finished hearth
surface. This clearance cannot be reduced by adding
shields.
WinterWarm Fireplace Insert or System
Backer Board
Tile
FP1117
WW
tile/wood trim
5/23/01 djt
FP1117
27