Electrical Box Connection; Remote On/Off Switch Installation; Alternate Switch Location - Majestic fireplaces DVRTSB Installation And Operating Manual

Bay window rear/top convertible direct vent fireplaces
Table of Contents

Advertisement

DVRTSB Bay Window Fireplace
EB-1 Electrical Box
The fireplace, when installed, must be elec-
trically connected and grounded in accord-
ance with local codes or, in the absence
of local codes, with the current CSA C22.1
Canadian Electrical Code
For USA installations follow the local
codes and the national electrical code
ANSI/NFPA No. 70.
It is strongly suggested that the wiring of
the EB-1 Electrical Junction Box be carried
out by a licensed electrician.
Ensure that the power to the supply line
has been disconnected before commenc-
ing this procedure.
The EB-1 Electrical junction box has been supplied
standard on this model to allow for the easy connection
of an optional fan kit. (Fig. )
To connect the EB-1 box to the house electrical supply
follow the steps below.
1. Remove the front cover of the EB-1 box.
2. Remove the plug socket assembly from the EB-1
box.
3. Feed the supply line in from the outside through the
electrical knock-out.
4. Connect the ground wire of the supply line to the
green screw of the socket assembly.
5. Connect the white wire of the power line to the
chrome screw of the socket assembly.
6. Connect the black wire of the power supply line to
the brass screw (polarized) of the socket assembly.
7. Refit the socket assembly back into the electrical
box and replace the cover plate.
8. The EB-1 electrical junction box is now ready to
supply power to the FK12 or FK24 fan kits, if fitted.
Electrical Box (EB-1)
Retaining
Screw
Fig. 6 EB-1 electrical box.
8
1¹⁄₂"
Gas
Inlet
Holes
FK24 Fan
Kit
Mounting
Studs
FP1375
FP1375
EB-2
7/03

Remote ON/OFF Switch Installation

1. Thread the wiring through the holes on the end
panels of the appliance. Take care not to cut the wire
or insulation on metal edges. Route the wire to
a conveniently located receptacle box.
2. Attach the wire to the ON/OFF switch and install the
switch into the receptacle box.
3. Connect the other ends of the wire to the gas
control valve. (Fig. 7)
Remote ON/OFF Switch or Ther-
mostat or Remote Control
Fig. 7 Remote switch wiring diagram.

Alternate Switch Location

The remote switch can be installed on the front/side of
the access door. Simply mount the switch to the bracket
provided and screw the bracket to either side of the
frame, lining up the screws with the pre-punched holes.
(Fig. 8)
Fig. 8 Alternate switch location.
TP
Gas
TH
Control
Valve
TP
TH
FP1376
FP1376
remote switch
7/03
FP1377
10003848

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents