Introduction & Specifications - Dyna-Glo ANSI Z83.7-2000 Instruction Manual

Propane construction heater
Table of Contents

Advertisement

Dyna-Glo Propane Forced Air Construction Heaters
The heater is designed and approved for use as a construction heater under ANSI Z83.7., CSA2.14
It is hard to anticipate every use which may be made of this heater.
FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat producing products in specific applications.
Your local authority can advise you about these.
IMPORTANT: Read this user's manual carefully and completely before trying to operate or
service this heater. Improper use of this heater can cause serious injury or death from fire,
explosion and carbon monoxide poisoning.
This is a direct-fired forced-air construction heater for either indoor or outdoor use. Its intended use
is primarily the temporary heating of buildings or structures under construction, alteration or repair.
All the products of combustion generated by the heater are forced through the heater and released
into the area being heated. This heater operates at approximately 98%+ combustion efficiency but
still produces a small amount of carbon monoxide. Humans can tolerate small amounts of carbon
monoxide for short periods. Carbon monoxide can build up in a heated space and failure to provide
adequate ventilation could result in poisoning or death.
WARNING: Not for use with ductwork.
SPECIFICATIONS:
Model No.
Input Rating
Type of Gas
Gas Supply Pressures
to Regulator Maximum Cylinder Pressure
Minimum (for purpose
of Input Adjustment)
Manifold Pressure
Gas Consumption
Electrical Input
Unload
Amperage
Load
Unload
Fan
Load
Ignition
Spark Gap
Size (L x W x H)
Weight
RMC-FA40DLX
RMC-FA40A
RMC-FA(50A)
40,000 Btu/hr
30,000 Btu/hr
-
50,000 Btu/hr
Propane
Propane
Cylinder Pressure
5psig
5psig
11" W.C.
10" W.C.
1.9lbs/hr
2.3lbs/hr
1.4lbs/h
3.3lbs/hr
120V, 60Hz, 1 Ø
120V, 60Hz, 1 Ø
0.35A
0.58A
0.63A
0.75A
3550rpm
3570rpm
3000rpm
3300rpm
Piezo/Manual Spark Continuous Spark
0.16"
0.16"
18.1" x 7.7" x 12.8" 18.1" x 7.7" x 12.8" 25.12" x 9" x 15.5" 25.12" x 9" x 15.5"
15.2lbs (6.9kg)
15.2lbs (6.9kg)
CHECK WITH YOUR LOCAL
-
RMC-FA100DLX
RMC-FA100A
70,000 Btu/hr
100,000 Btu/hr
Propane
Cylinder Pressure
5psig
9.5" W.C
4.6lbs/hr
3.3lbs/h - 5.6lbs/hr
120V, 60Hz, 1 Ø
0.6A
0.8A
3580rpm
3300rpm
Continuous Spark
0.16"
22.7lbs (10.3kg)
RMC-FA150DLX
RMC-FA150A
120,000 Btu/hr
150,000 Btu/hr
Propane
Cylinder Pressure
5psig
8" W.C.
7lbs/hr
5.6lbs/hr
120V, 60Hz, 1 Ø
0.6A
0.8A
3580rpm
3300rpm
Continuous Spark
0.16"
22.7lbs (10.3kg)
Page 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents