Table 2 Definition of Fields 
Field 
EP 
FC(bit2­bit 9) 
CC (bit10­bit 25) 
OP 
Pyramid Wiegand format 
Several alternatives exist for customers who require more codes. The first is to switch to Keri's standard 39 bit 
Pyramid format. This 39 bit Wiegand format contains 17 bits for the facility code field and 20 bits for the ID 
number field. Mathematically these 17 facility code bits allow for a total of 131,072 (0 to 131,071) facility codes, 
while the 20 ID number bits allow for a total of 1,048,576 (0 to 1,048,575) individual ID's within each facility 
code. Since there are so many facility codes in the Pyramid format, a new facility code may be selected for 
each project. Additionally the large number of ID's per facility code makes the Pyramid format ideal for very 
large projects. For added security, Keri Systems tracks credential coding to ensure that no duplication occurs. 
Table 3 provides a summary of the Pyramid Wiegand format. 
Table 3 Pyramid Wiegand Format 
Custom Wiegand Formats 
The second alternative is to create a custom Wiegand format. Typically, up to 64 bits are available for creating 
a  custom  Wiegand  format.  With  certain  limitations,  formats  with  greater  than  64  bits  may  be  created.  If  a 
customer currently has a custom Wiegand format from Wiegand or from other proximity manufacturers, Keri 
can normally match that format. Although the customer is primarily responsible for custom format card coding, 
as an added benefit Keri Systems tracks card coding for additional security. Table 4 provides an example of 
one possible custom Wiegand format. 
Table 4 Example of a Custom Wiegand Format 
10.6 Daylight Saving Time (Time Zone Settings) 
The Daylight Saving Time (DLST) is a widely used system of adjusting the official local time forward to save 
energy. The uniform time adopted during the implementation of this system is known as the DLST. Typically 
clocks are adjusted forward one hour in the summer to make people early to bed and early to rise so as to 
make  full  use  of  illumination  resources  and  save  electricity.  Clocks  are  adjusted  backward  in  autumn.  The 
specific DLST regulations vary with countries. At present, the DLST system is adopted every year by about 
110 countries in the world.
Honeywell VISTA Series Products User Manual 
EP 
FC 
Even  Parity  bit  (EP)  is  judged  based  on  field  1  to  13  bit.    EP  is  1  if  the 
number of "1" is even; otherwise, EP is 0. 
Facility Code (0­255) 
Bit 2 is the Most Significant Bit (MSB). 
Card Code (0­65 535). Bit10 is the MSB. 
The value of Odd Parity bit is determined by 14–26 bit. OP is 1 if the number 
of "1" is even; otherwise, OP is 0. 
Bit Number 
Bit 1 
Even parity over bits 2 to 9 
Bits 2 to 18 
Facility code (0 to 131,071); Bit 2 is MSB 
Bits 19 to 38 
ID Number (0 to 1,048,575); Bit 19 is MSB 
Bit 39 
Odd parity over bits 20 to 38 
Bit Number 
Bit 1 
Even parity over bits 2 to 22 
Bits 2 to 9 
OEM code (0 to 255); Bit 2 is MSB 
Bits 10 to 21 
Facility code (0 to 4,096); Bit 10 is MSB 
Bits 22 to 43 
ID Number (0 to 524,287); Bit 22 is MSB 
Bit 44 
Even parity over bits 23 to 43 
CC 
Purpose 
Meaning 
Purpose 
41 
OP 