Model Number Description

Model Number Descriptions
All products are identified by a
multiple character model number that
precisely identifies a particular type of
unit. An explanation of the
alphanumeric identification code is
provided. Its use will enable the
owner/operator, installing
contractors, and service engineers to
define the operation, specific
components, and other options for
any specific unit.
When ordering replacement parts or
requesting service, be sure to refer to
the specific model number and serial
number printed on the unit
nameplate.
Digit 1 — Unit Type
Y
=
Packaged Gas/Electric
Digit 2 — Efficiency
S
=
Standard Efficiency
H
=
High Efficiency
Digit 3 — Airflow Configuration
D
=
Downflow
H
=
Horizontal
Digit 4, 5, 6 — Nominal Gross
Cooling Capacity (MBh)
150 = 12½ Tons, 60Hz
155 =
15 Tons, 50Hz
180 = 15 Tons, 60Hz
175 =
17½ Tons, 50Hz
210 = 17½ Tons, 60Hz DOE 2018
200 =
20 Tons, 50Hz
240 = 20 Tons, 60Hz
250 =
25 Tons, 50Hz
300 = 25 Tons, 60Hz DOE 2018
Digit 7 — Major Design
Sequence
Microchannel Type Condenser 
F
=
25
Coils
G
=
ASHRAE 90.1-2013 (Fan/
Compressor Staging)
Microchannel Type Evaporator 
and Condenser Coils
Digit 8 — Voltage Selection
3
=
208-230/60/3
4
=
460/60/3
W =
575/60/3
K
=
380/60/3
D
=
380-415/50/3
Digit 9 — Unit Controls
R
=
Reliatel
Digit 10 — Heating Capacity
H
=
Gas Heat - High
L
=
Gas Heat - Low
V
=
Gas Heat - SS Ht Ex - Modulating
X
=
Gas Heat - SS Ht Ex - Low
Z
=
Gas Heat - SS Ht Ex - High
RT-SVX26R-EN
Digit 11 — Minor Design
Sequence
Digit 12, 13 — Service Sequence
00 =
None
01 =
18mm Microchannel Condenser
Coil
Note: '01' only available on select
models.
Digit 14 — Fresh Air Selection
0
=
No Fresh Air
D
=
Econ Dry Bulb w/ Barometric
Relief
F
=
Econ Reference Enthaply w/
Barometric Relief
H
=
Econ Comparative Enthaply w/
Barometric Relief
K
=
Low Leak Econ w/ Barometric
Relief
M =
Low Leak Econ Reference
Enthalpy w/ Barometric Relief
P
=
Low Leak Econ Comparative
Enthalpy w/ Barometric Relief
Digit 15 — Supply Fan/Drive
Type/Motor
0
=
Standard Motor
1
=
Oversized Motor
3
=
High Efficiency Motor
6
=
Single Zone Variable Air Volume
Standard Motor
7
=
Multi-Speed Standard Motor
8
=
Single Zone Variable Air Volume
Oversized Motor
9
=
Multi-Speed Oversized Motor
A
=
Single Zone Variable Air Volume
Standard Motor w/ Shaft
Grounding Ring
B
=
Multi-Speed Standard Motor w/
Shaft Grounding Ring
C
=
Single Zone Variable Air Volume
Oversized Motor w/ Shaft
Grounding Ring
D
=
Multi-Speed Oversized Motor w/
Shaft Grounding Ring
E
=
VAV Supply Air Temperature
Control - Standard Motor
13
or
F
=
VAV Supply Air Temperature
Control - Oversized Motor
G
=
VAV Supply Air Temperature
Control - Standard Motor w/ Shaft
Grounding Ring
H
=
VAV Supply Air Temperature
Control - Oversized Motor w/
Shaft Grounding Ring
Digit 16 — Hinged Service
Access / Filters
0
=
Standard Panels/Standard
Filters
A
=
Hinged Access/Standard Filters
B
=
Standard Panels/MERV 8 Filters
C
=
Hinged Access/MERV 8 Filters
D
=
Standard Panels/MERV 13 Filters
E
=
Hinged Access/MERV 13 Filters
1
1
1
1
1
1
6
6
22
22
6
6
6
6
Digit 17 — Condenser Coil
Protection
0
=
Standard Coil
1
=
Standard Coil With Hail Guard
4
=
CompleteCoat™Condenser Coil
5
=
CompleteCoat™Condenser Coil
with Hail Guard
Digit 18 — Through The Base
Provisions
0
=
No Through The Base Provisions
A
=
Through The Base Electric
B
=
Through The Base Gas
C
=
Through The Base Electric/Gas
D
=
Through The Base Access
Digit 19 — Disconnect Switch/
11
Circuit Breaker
0
=
No Disconnect/circuit break
1
=
Unit Mounted Non-Fused
Disconnect Switch
2
=
Unit Mounted Circuit Breaker
Digit 20 — Convenience Outlet
Option
0
=
Without Convenience Outlet
A
=
Unpowered Convenience Outlet
B
=
Powered Convenience Outlet
Digit 21 — Communications
Options
0
=
Without Communications Options
1
=
Trane Communications Interface
2
=
Lontalk Communications
6
Interface
6
=
Building Automation Control
Network Communications
Interface
7
=
Air-Fi™ Wireless Communications
Digit 22 — Refrigeration System
Option
0
=
Standard refrigeration system
B
=
Dehumidification (Hot Gas
4,13
Reheat)
Digit 23 — Refrigeration Controls
0
=
Without Refrigeration Controls
9,
18
1
=
Frostat
Digit 24 — Smoke Detector
0
=
Without Smoke Detector
A
=
Return Air Smoke Detector
B
=
Supply Air Smoke Detector
C
=
Return/Supply Air Smoke
Detector
D
=
Plenum Smoke Detector
Digit 25 — System Monitoring
Controls
0
=
No Monitoring Controls
1
=
Clogged Filter Switch
9
2
=
Fan Failure Switch
3
=
Discharge Air Sensing
4
=
Clogged Filter Switch and Fan
9
Failure switch
5
=
Clogged Filter Switch and
Discharge Air Sensing
12
12
5
5
6,
15
24
2,10
19
9
9
9
5