INSTALLATION

Pre-installation
Before installing the rangehood, peel off any protective
coating and remove the filters.
Location
The hood is to be mounted on the wall. When installed,
the hood must be not less than 60cm above electric
burners or 65cm above gas or mixed-fuel burners.
DISTANCE FROM HOOD BAST TO TOP OF HOB
HOB TYPE
If the instructions of the hob specify a greater distance
than the minimum above, then that shall be the minimum
height for installation.
273
30
130
55
Min 650mm
Max 800mm
Installation
1.
Using a spirit level mark a vertical centre line on
the wall where the hood is to be positioned, and a
horizontal line at the hood base position.
NOTE: The height of the underside of the hood body
must be a minimum of 600mm* to a maximum height
of 800mm.
*If the instructions of the hob specify a greater distance
than the minimum above, then that shall be the minimum
height for installation.
2.
Mark the location for the flue cover wall mounting
brackets and rangehood mounting points and anti-tilt
fixing points above the hood base using the hood
base as a reference point.
Failure to install the screws or fixing device in accordance
with these instructions may result in electrical hazards.
140
Top mounting bracket for T-piece(Optional part)
Bottom mounting bracket for flue cover
(Required where ceiling cornice is in place)
192
Rangehood mounting points
350
Min 600mm
Max 800mm
Fig.5
Anti tilt fixing points
INSTALLATION