Agilent Technologies 75000 Series User's Manual And Service Manual
Agilent Technologies 75000 Series User's Manual And Service Manual

Agilent Technologies 75000 Series User's Manual And Service Manual

Vxi c-size high power mainframe
Hide thumbs Also See for 75000 Series:

Advertisement

Quick Links

Agilent Technologies 75000 Series User's Manual And Service Manual

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies 75000 Series

  • Page 1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
  • Page 2 Agilent 75000 Series C Agilent E1401B High Power Mainframe User’s Guide and Service Manual Where to Find it - Online and Printed Information: System installation (hardware/software) ....VXIbus Configuration Guide* Agilent VIC (VXI installation software)* Module configuration and wiring .......This Manual VXIplug&play programming ......
  • Page 5: Table Of Contents

    Contents Warranty..........................3 Safety Symbols ........................4 WARNINGS ........................4 Declaration of Conformity ....................5 User Notes ........................... 6 Chapter 1 Using the Mainframe ......................9 Mainframe Description ....................... 9 Line Voltage and Input Power .................... 9 Air Flow ..........................10 Variable Speed Fan ....................
  • Page 6 Notes: Contents...
  • Page 7: Warranty

    Certification Agilent Technologies, Inc. certifies that this product met its published specifications at the time of shipment from the factory. Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology (formerly National Bureau of Standards), to the extent allowed by that organization's calibration facility, and to the calibration facilities of other International Standards Organization members.
  • Page 8: Safety Symbols

    Agilent Technologies, Inc. assumes no liability for the customer's failure to comply with these requirements. Ground the equipment: For Safety Class 1 equipment (equipment having a protective earth terminal), an uninterruptible safety earth ground must be provided from the mains power source to the product input wiring terminals or supplied power cable.
  • Page 9: Declaration Of Conformity

    This DoC applies to above-listed products placed on the EU market after: December 31, 2003 Date Tan, Boon Juan Quality Manager For further information, please contact your local Agilent Technologies sales office, agent or distributor, or Agilent Technologies Deutschland GmbH, Herrenberger Straße 130, D 71034 Böblingen, Germany.
  • Page 10: User Notes

    Notes:...
  • Page 11 Notes:...
  • Page 12 Notes:...
  • Page 13: Using The Mainframe

    Chapter 1 Using the Mainframe Mainframe Description The Agilent E1401B mainframe is designed in full compliance with the VXIbus specification (Rev. 1.4) and VMEbus system specification (Rev. C.1). The mainframe contains 13 slots for plug-in modules and can be rack mounted in either the forward or reverse position.
  • Page 14: Air Flow

    Air Flow The air flow into the plug-in module slots in the Agilent E1401B mainframe is significantly more than previous Agilent mainframes. The mainframe supplies each of the 13 slots with enough air to cool 60 Watts while maintaining only a 10°C rise across a typically dense module. Up to 75 Watts per slot may be dissipated if a 15°C rise is acceptable across a typically dense module.
  • Page 15: Variable Speed Fan

    Variable Speed Fan Normally, the speed of the four internal circulation fans is determined by the ambient temperature of the air drawn into the mainframe. One fan cools the power supply module and three fans cool the VXI modules inserted into the mainframe.
  • Page 16: Rear Panel Auxiliary Connector

    Rear Panel Auxiliary Connector A 25-pin “D” connector is provided on the rear panel of the mainframe to allow monitoring of power supply voltages and other functions. The pinouts for this connector are shown in the following table. Using the Mainframe Chapter 1...
  • Page 17 The +5 volt output lets you power external TTL circuitry if required. The maximum current allowed from this supply is 1.0A. +12V The +12 volt output lets you power a battery charging circuit to provide a source for the +5V STDBY input. The maximum current allowed from this supply is 1.0A.
  • Page 18: Remote Standby Switch

    Remote Standby The remote standby switch connection is provided to let you turn the mainframe ON or put it in STANDBY mode remotely. These two Switch connections are wired in parallel with the front panel ON/STANDBY switch. This means that the front panel switch must be in STANDBY position for the remote switch to function correctly.
  • Page 19: Installing The Power Line Fuse

    Installing the Power Line Fuse The mainframe is shipped with a 15A fast blow (15AF) fuse (Agilent Part Number 2110-0054) already installed. This fuse is suitable for all line voltages. Figure 1-5 shows how to replace the fuse if necessary. Figure 1-5.
  • Page 20: Power Cords

    Power Cords Table 1-1 shows the power cords and their Agilent part numbers. Table 1-1. Power Cords for the Agilent E1401B Country Part Number Volts Rated Amps Type U.K. 8120-5392 250 VAC 10 A Right Angle Connector Australia 8120-5393 250 VAC 10 A Right Angle Connector Europe...
  • Page 21 WARNING For protection from electric shock hazard, power cord ground must not be defeated. The front power switch on this instrument does not disconnect all power from internal circuits. In case of emergency, the operator may need to disconnect the power to this mainframe. Do not block the operator’s access to the power cord, or (if installed in a rack) to the circuit breaker which supplies power to the mainframe.
  • Page 22: Agilent E1401B Safety Grounding Information

    Agilent E1401B Safety Grounding Information WARNING For protection from electrical shock when operating at mains frequencies greater than 66 Hz, connect the chassis ground terminal to permanent earth ground. AVERTISSMENT Risque de Choch électrique. Si la fréquence du secteur est supérieure à...
  • Page 23 Notes: Using the Mainframe 19 Chapter 1...
  • Page 24: Replaceable Parts And Assemblies

    Chapter 2 Replaceable Parts and Assemblies There are no user sevicable parts in the Agilent E1401B. Repair is limited to replacing the power supply module, the backplane module, or other mechanical parts only. Module The power supply is available on an exchange basis. The backplane assembly should be replaced and not repaired (no exchange on the Replacement backplane).
  • Page 25: Agilent E1401B Replaceable Parts List

    Agilent E1401B Replaceable Parts List Reference Agilent Part Total Description Designator Number Qty. E1401-66511 PC Backplane Assembly E1401-69202 Power Supply; Power-650 Watts; 8 Outputs B1-B4 3160-0864 Fan - Tubeaxial - 12 VDC BZL1 E1401-04306 Front Bezel - Bottom BZL2 E1401-04304 Bezel - Top BZL3 E1401-04301...
  • Page 26 Figure 2-1. Mainframe Replaceable Parts 22 Replaceable Parts and Assemblies Chapter 2...
  • Page 27 Figure 2-2. Power Supply and Rear Panel Replaceable Parts Replaceable Parts and Assemblies 23 Chapter 2...
  • Page 28 Figure 2-3. Fan Assembly and Rear Panel Replaceable Parts Chapter 2 Replaceable Parts and Assemblies...
  • Page 29 Notes: Replaceable Parts and Assemblies 25 Chapter 2...
  • Page 30: Agilent E1401B Specifications

    Appendix A Agilent E1401B Specifications The Agilent E1401B High-Power mainframes are 100% compatible with VXIbus specification revision 1.4. Overall Mainframe Size Mainframe Weight Agilent E1401B: 22 Kg (48.5 lbs) with no modules installed. Module Size Thirteen (13) C-Size slots. The mainframes also accept A- or B- Size modules using the optional Agilent E1403 Module Carrier.
  • Page 31 Power Supply Outputs DC Output Peak DC Output P-P Dynamic CD Current Limit Voltage Current (*IMP) Current (**IMD) (supply shuts down) 40°C 55°C 9.0A 70 - 80A +12V 2.5A 14 - 18A -12V 2.5A 14 - 18A +24V 5.0A 15 - 19A -24V 5.0A 12 - 16A...
  • Page 32 Humidity Exceeds MIL-T-28800D test limit 3.7.2, 40 ºC and 95% RH. Temperature Range Exceeds MIL-T-28800D Test Limits 3.7.2, Non-operating:-40ºC to +75ºC Operating: 0ºC to 55ºC Altitude 3000m Installation category Pollution Degree 2 Indoor Use Statement Shock and Vibration Meets the following MIL-T-28800D Test Limits: Vibration test limits: 3.7.4.1 and 4.5.5.3.1 Shock Test Limits: 3.7.5.1 and 4.5.5.4.1 Bench handling test limits: 3.7.5.3 and 4.5.5.4.3...
  • Page 33 EMC Testing Within the requirements of MIL-STD-461 methods CE01, CE02 (relaxed 30 dB below 2 MHz, relaxed 10 dB between 2 and 15 MHz), CS01, CS02, CS06, RE01 (relaxed 10 dB), RE02, and RS02, RS03. Meets requirements of CISPR 11 Level A. Module Weight Maximum 3.5 Kg (7.7 lbs) per slot to comply with vibration and shock specifications.
  • Page 34 Notes: Agilent E1401B Specifications Appendix A...
  • Page 35: Index

    Index , 10 , 12–13 Air Flow Rear Panel Auxiliary Connector , 14 Remote Standby Switch , 20 Replaceable Parts List Certification , 19 Cleaning Fan Filters , 17 , 27 Safety Grounding Information Cooling Provided Safety Warnings , 25–27 Specifications Declaration of Conformity Documentation History...
  • Page 36 Notes: Index...
  • Page 37 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...

This manual is also suitable for:

E1401b

Table of Contents