Command details

Commands sent from the control computer to the R-1000
The following three types of commands are sent from an external device to the R-1000.
Control (execution) commands
These commands are used to adjust the volume and to make various settings.
Request commands
These commands are used to check the current state of the R-1000's settings.
After performing a control operation, you should use a request command to check the state of the settings.
Reply commands
Commands such as "ack" and "ERR" are in this category. These commands are used to reply to the R-1000 when a request
command is used.

Control Commands

STC : Stop
Function Stop recording/playback.
Syntax
stxSTC; (command syntax : type 1)
PYC : Play
Function Starts playback. Starts recording when recording is paused.
Syntax
stxPYC; (command syntax : type 1)
REC : Record
Function Make the unit to REC pause status.
Syntax
stxREC; (command syntax : type 1)
LCC : Locate
Function Jumps to specified location.
Syntax
stxLCC:HHhMMmSSsFFf; (command syntax : type 2)
HH:hour
MM:minute
SS:second
FF:frame
Example)
stxLCC:01h48m24s10f;
Jumps to 01:48:24.10
* The value of h/m/s/f not specified in the syntax will be [00] automatically.