Permanent magnet motor

These are additional warnings concerning permanent magnet motor drives. Ignoring
the instructions can cause physical injury or death, or damage to the equipment.
Note: Controlling a permanent magnet motor is only allowed using the ACS800
Permanent Magnet Synchronous Motor Drive Control Program.

Installation and maintenance work

WARNING! Do not work on the drive when the permanent magnet motor is rotating.
Also, when the supply power is switched off and the inverter is stopped, a rotating
permanent magnet motor feeds power to the main circuit of the drive including the
input power terminals.
Before installation and maintenance work on the drive:
• Stop the motor.
• Ensure that the motor cannot rotate during work.
• Ensure that there is no voltage on the drive power terminals:
Alternative 1) Disconnect the motor from the drive with a safety switch or by other
means. Measure that there is no voltage present on the drive input, output or DC
terminals (U1, V1, W1, U2, V2, W2, UDC+, UDC-).
Alternative 2) Measure that there is no voltage present on the drive input, output
or DC terminals (U1, V1, W1, U2, V2, W2, UDC+, UDC-). Ground the drive output
terminals temporarily by connecting them together as well as to the PE.
Alternative 3) If possible, both of the above.

Start-up and operation

WARNING! Do not run the motor over the rated speed. Motor overspeed leads to
overvoltage which may damage the capacitors in the intermediate circuit of the drive.