For information about installing the grounding cable, see the NFX350 Hardware Guide available at:
https://www.juniper.net/documentation/en_US/release-independent/junos/information-products/pathway-pages/nfx-series/product/
You can mount the device a four-post rack by using the mounting brackets provided with the device.
NOTE:
The device weighs approximately 9.4 lb (4.3 kg). Two persons are required for mounting the device.
NOTE:
Ensure that the rack is in its permanent location, allowing adequate clearance for airflow and maintenance,
and secured to the building structure.
NOTE:
If you are mounting multiple units in the rack, mount the heaviest unit at the bottom and mount the
other units from bottom to top in the order of decreasing weight.
CAUTION:
other end to a site ESD point.
To mount the device on a rack:
1. Align the mounting brackets along the front or rear of the side panels of the chassis— depending on whether you will
front-mount or rear-mount the device—and attach the mounting brackets to the chassis by using the mounting bracket
screws. Tighten the screws.
2. Have one person grasp both sides of the device, lift the device, and position it in the rack, aligning the mounting bracket
holes with the threaded holes in the rack rail. Align the bottom hole in each mounting bracket with a hole in each rack
rail, making sure that the chassis is level.
Figure 3: Attaching the Device to the Rack
3. Have the second person use the rack-mounting screws (and cage nuts and washers if your rack requires them) to attach
the mounting brackets to the rack.
Wrap and fasten one end of the ESD grounding strap around your wrist and connect the
5