Download Print this page

C2AI HD35 Product Information page 35

Wireless, wi-fi/ethernet

Advertisement

Product information Wireless data loggers
TAB. 7: Capacity of the internal memory of the data loggers in housing for
outdoor
Number of samples that can
Model
HD35EDW 7P/1 TC
HD35EDW 7P/2 TC
HD35EDW 7P/3 TC
HD35EDW N/1 TC
HD35EDW N/2 TC
HD35EDW N/3 TC
HD35EDW N TV
HD35EDW K/4 TC
HD35EDW 1 TV
HD35EDW 1 TVI
HD35EDW 1N TC
HD35EDW 17P TC
HD35EDW 1N TV
HD35EDW 1N TVI
HD35EDW 1N/2 TC
HD35EDW 14bN TC
HD35EDW 14b7P TC
HD35EDW R TC
HD35EDW 1NR TC
HD35EDW 7PR TC
HD35EDW 1N7PR TC
HD35EDW RP TC
HD35EDW P TC
HD35EDW NP TC
HD35EDW 1NP TC
HD35EDW 1NL TC
HD35EDW S TC
HD35EDW S/2 TC
HD35EDW S/3 TC
HD35EDW DP TC
HD35EDW 1NI2 TCV
HD35EDW 1NB... TV
HD35EDW 1NB...I... TCV
HD35EDW 1NB...F TCV
HD35EDW WBGT
HD35EDW H
HD35EDW-MB
List of the quantities:
(*)
AH: absolute humidity
CO
: carbon dioxide
2
D
: daily rainfall quantity
P
D
: daily solar radiation (Wh/m
R
F
: fluid level
L
H
: leaf wetness
LEAF
I: illuminance
I
: rainfall rate (mm/h)
P
MR: mixing ratio
mV: pyranometer output in mV
P: rainfall quantity
PAR: Photosintetically Active Radiation
(**)
One sample consists of all the quantities measured and calculated by the data logger at the same instant of acquisition. For example,
the model HD35EDW1NTC measures two quantities and calculates five quantities (the derived humidity quantities) and one sample
includes one temperature measure and six humidity measurements (the relative humidity measure plus the five derived quantities).
(***)
The minimum logging interval may be smaller if the data logger only stores some of the available quantities.
(****)
CO
measurement is updated every 15 s.
2
be stored
(**)
68,000
from 52,000 to 68,000
from 42,000 to 68,000
68,000
52,000
42,000
68,000
from 36,000 to 68,000
68,000
68,000
24,000
24,000
24,000
24,000
22,000
22,000
22,000
42,000
24,000
36,000
22,000
28,000
36,000
28,000
22,000
22,000
52,000
36,000
26,000
28,000
30,000
30,000
26,000
26,000
22,000
from 28,000 to 58,000
from 14,000 to 52,000
P
: atmospheric pressure
ATM
P
: relative pressure
REL
PVP: partial vapour pressure
R: solar radiation (pyranometer)
2
)
RH: relative humidity
T: temperature
T
: dew point
D
T
: globe thermometer temperature
G
T
: natural ventilation wet bulb temperature
NW
T
: wet bulb temperature
W
WBGT: WBGT index
VWC: soil volumetric water content
Minimum
logging interval
1 s
(***)
2 s
5 s
(***)
1 s
1 s
1 s
1 s
5 s
(***)
1 s
1 s
1 s
1 s
1 s
1 s
1 s
2 s
2 s
1 s
1 s
1 s
1 s
1 s
1 s
1 s
1 s
1 s
1 s
1 s
1 s
1 s
1 s
(
****
)
1 s
(
****
)
1 s
(
)
1 s
****
2 s
5 s
(***)
depends on the inputs configuration
1 s
depends on the sensors connected
Stored quantities
(*)
T
T
T
T
T
T
T
T
RH
RH
T, RH, T
, T
, AH, MR, PVP
D
W
T, RH, T
, T
, AH, MR, PVP
D
W
T, RH, T
, T
, AH, MR, PVP
D
W
T, RH, T
, T
, AH, MR, PVP
D
W
T, RH, T
, T
, AH, MR, PVP
D
W
T, RH, T
, T
, AH, MR, PVP, P
D
W
ATM
T, RH, T
, T
, AH, MR, PVP, P
D
W
ATM
R, D
, mV
R
T, RH, T
, AH, R, D
, mV
D
R
T, R, D
, mV
R
T, RH, T
, AH, R, D
, mV
D
R
R, D
, mV, P, D
, I
R
P
P
P, D
, I
P
P
T, P, D
, I
P
P
T, RH, T
, AH, P, D
, I
D
P
P
T, RH, T
, T
, AH, MR, PVP, H
D
W
LEAF
T, VWC
T, VWC
T, VWC
F
, P
, P, D
, I
L
REL
P
P
T, RH, T
, AH, I
D
T, RH, T
, AH, CO
D
2
T, RH, T
, AH, I, CO
D
2
T, RH, T
, AH, PAR, CO
D
2
T, T
, T
, RH, T
, WBGT
NW
G
D
35

Advertisement

loading