Physical data EWAP-AJYNN/A with option OPRN/OPLN
Unit size
Cooling capacity (1)
Power input (1)
COP
Single screw compressors
Refrigerant circuits
Refrigerant charge
Oil charge
Min % of capacity reduction
Condenser fans
N° of fans / Nominal power fan
Fan speed
Diameter
Total air flow
Evaporator
Evaporator / Water volume
Max operating pressure
Water connections diameter
Condenser coil
Coil type
Weight and dimension
Std unit shipping weight for unit + OPRN
Std unit operating weight for unit + OPRN
Std unit shipping weight for unit + OPLN
Std unit operating weight for unit + OPLN
Unit length
Unit width
Unit height
Unit size
Cooling capacity (1)
Power input (1)
COP
Single screw compressors
Refrigerant circuits
Refrigerant charge
Oil charge
Min % of capacity reduction
Condenser fans
N° of fans / Nominal power fan
Fan speed
Diameter
Total air flow
Evaporator
Evaporator / Water volume
Max operating pressure
Water connections diameter
Condenser coil
Coil type
Weight and dimension
Std unit shipping weight for unit + OPRN
Std unit operating weight for unit + OPRN
Std unit shipping weight for unit + OPLN
Std unit operating weight for unit + OPLN
Unit length
Unit width
Unit height
Note: (1) Nominal cooling capacity and power input are based on: 12 / 7 ° C entering / leaving evaporator water temperature;
35° C ambient temperature. The power input is for co mpressor only
(2) Unit C17 and C18 are longer than 14000 mm so beware of special transportation required.
850
900
kW
818,2
911,3
kW
311,5
346,9
2,63
2,63
2
2
2
2
kg
160
170
kg
40
40
12,5
12,5
%
kW
16/1,25
17/1,25
rpm
680
680
mm
800
800
3
m
/s
64,5
68,6
N° /l
1 / 271
1 / 256
bar
10,5
10,5
mm
219
219
Lanced fins – Internally spiral wound tubes
kg
5900
6170
kg
6185
6440
kg
6140
6410
kg
6425
6680
mm
8010
8910
mm
2230
2230
mm
2520
2520
C13
C14
1299,3
1365,6
kW
kW
499,0
529,9
2,60
2,58
3
3
3
3
kg
250
260
kg
60
60
%
8,3
8,3
kW
25/1,25
26/1,25
rpm
680
680
mm
800
800
3
m
/s
100,9
104,9
N° /l
1 / 432
1 / 432
bar
10,5
10,5
mm
273
273
Lanced fins – Internally spiral wound tubes
kg
9505
9625
kg
9980
10100
kg
9865
9985
10340
10460
kg
mm
12770
12770
2230
2230
mm
mm
2520
2520
.
950
C10
C11
981,1
1069,8
1137,3
378,6
418,0
453,6
2,59
2,56
2,51
2
2
2
2
2
2
180
185
190
40
40
40
12,5
12,5
12,5
18/1,25
19/1,25
20/1,25
680
680
680
800
800
800
72,6
76,7
80,7
1 / 256
1 / 270
1 / 270
10,5
10,5
10,5
219
219
219
6290
6525
6645
6560
6780
6900
6530
6765
6885
6800
7020
7140
8910
9810
9810
2230
2230
2230
2520
2520
2520
C15
C16
C17 (2)
1435,8
1522,5
1586,0
558,2
600,3
635,0
2,57
2,54
2,50
3
3
3
3
3
3
275
275
280
60
60
60
8,3
8,3
8,3
28/1,25
28/1,25
29/1,25
680
680
680
800
800
800
115,6
113
113
1 / 432
1 / 419
1 / 419
10,5
10,5
10,5
273
273
273
10060
10075
10410
10530
10520
10860
10420
10435
10770
10890
10880
11220
13670
13670
14570
2230
2230
2230
2520
2520
2520
D - KIMAC00512-09EN - 17/40
R-407C
C12
1202,1
463,4
2,59
3
3
240
60
8,3
24/1,25
680
800
96,8
1 / 278
10,5
219
9050
9320
9410
9680
11870
2230
2520
C18 (2)
1649,3
669,6
2,46
3
3
285
60
8,3
30/1,25
680
800
121
1 / 419
10,5
273
10470
10920
10830
11280
14570
2230
2520

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ewap 850-c18ajynn/a