Advanced Settings - Aube Technologies RLV4305 Owner's Manual

Table of Contents

Advertisement

Available languages

Available languages

Advanced settings

1. Press the Pgm button for 3 seconds.
2. To display the next parameter, press the
Pgm button.
3. To modify the displayed parameter, press
the Up or Down button.
4. To exit the menu, press the
not press any button for 1 minute.
Display
Temperature unit
Time format
Fan
Away temperature
Daylight saving
time
Year
Month
Day
Early start
Minimum setpoint
Maximum setpoint
Keypad lock
Fan
1
Place at Yes if you have a fan-forced heater (to prevent premature burnout of
the motor). Leave at No for better temperature regulation if you do not have a
fan-forced heater.
button or do
Parameter
1
41°F - 86°F (5.0°C - 30.0°C)
2
3
4
4
4
5
41°F - 86°F (5.0°C - 30.0°C)
41°F - 86°F (5.0°C - 30.0°C)
6
Options
°F / °C
12 hr / 24 hr
No / Yes
On / Off
00 - 99
01 - 12
01 - 31
On / Off
On / Off
7
The first parameter
appears when the
menu is displayed.
Default Setting
°F
12 hr
No
59°F (15.0°C)
Off
09
01
01
Off
41°F (5.0°C)
86°F (30.0°C)
Off

Hide quick links: