System Settings - Mitsubishi Electric MELSEC Q Series Programming Manual

Motion controller, real mode
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

3 POSITIONING DEDICATED SIGNALS
b15
SD500
Axis 16 Axis 15 Axis 14 Axis 13 Axis 12 Axis 11 Axis 10 Axis 9
SD501
Axis 32 Axis 31 Axis 30 Axis 29 Axis 28 Axis 27 Axis 26 Axis 25 Axis 24 Axis 23 Axis 22 Axis 21 Axis 20 Axis 19 Axis 18 Axis 17
(Note-1): The following range is valid.
(Note-2): Refer to APPENDIX of the "Q173D(S)CPU/Q172D(S)CPU Motion controller (SV22)
b15
b14
SD502
Axis 16 Axis 15 Axis 14 Axis 13 Axis 12 Axis 11 Axis 10 Axis 9
SD503
Axis 32 Axis 31 Axis 30 Axis 29 Axis 28 Axis 27 Axis 26 Axis 25 Axis 24 Axis 23 Axis 22 Axis 21 Axis 20 Axis 19 Axis 18 Axis 17
(Note-1): The following range is valid.
(2) Real mode axis information register (SD500, SD501)
This signal is used to store the information used as a real mode axis at the time
of switching from real mode to virtual mode.
The real mode axis information does not change at the time of switching from
virtual mode to real mode.
b14
b13
b12
b11
b10
Q172DSCPU
: Axis No.1 to 16
Q172DCPU(-S1) : Axis No.1 to 8
Programming Manual (VIRTUAL MODE)" for the expression method of the axis
number corresponding to each bit of word data.
(3) Servo amplifier loading information (SD502, SD503)
The mounting status of the servo amplifier is checked at the power supply on or
reset of the Multiple CPU system and its results are stored in this device.
If communication with servo amplifier stops, it is reset.
The mounting status of changed axis after the power supply on is stored.
b13
b12
b11
b10
b9
Q172DSCPU
: Axis No.1 to 16
Q172DCPU(-S1) : Axis No.1 to 8
(a) Servo amplifier mounting status
1) Mounting status
• Mounted .......... The servo amplifier is normal. (Communication with
• Not mounted .... The servo amplifier is not mounted.
2) The system settings and servo amplifier mounting status are shown
below.

System Settings

Used (axis No. setting)
Unused
b9
b8
b7
b6
b5
Axis 8
Axis 7
Axis 6
b8
b7
b6
b5
b4
Axis 8
Axis 7
Axis 6
Axis 5
the servo amplifier is normal.)
The servo amplifier control circuit power is off.
Normal communication with the servo amplifier is
not possible due to a connecting cable fault, etc.
Mounted
1 is stored
3 - 69
............................. Monitor device
b4
b3
b2
b1
b0
Axis 5
Axis 4
Axis 3
Axis 2
Axis 1
Real mode axis information
0 : Except real mode axis
1 : Real mode axis
............................. Monitor device
b3
b2
b1
b0
Axis 4
Axis 3
Axis 2
Axis 1
Servo amplifier mounting status
0: Not mounted
1: Mounted
Servo amplifier
Not mounted
0 is stored
0 is stored

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents