Navien LCB700-21RS Installation & Operation Manual page 64

Condensing blue flame oil-fired boiler
Table of Contents

Advertisement

Item
10. Oil CMPS Rate
11. Service Notif
Time
12. Service Notif
Cycle
13. Factory Reset
14. P/W Change
Combi Models
Item
1. Supply MIN Set-
point
2. Supply MAX Set-
point
3. CH Burning Off
Diff
4. CH Buring On Diff
64
Operating the Boiler
Description
Set the oil consumption
compensation rate.
Setting range : -25% – 25%
Default : 0 %
Set the time for service notification.
Setting range: 30 – 3650 days (10
years)
It can be set in 10 day increments.
Default: 1820 days (5 years)
Set the service notification according
to the operating times.
Setting range: 300 – 36500 cycles
It can be set in 100 cycle
increments.
Default: 18200 cycles
Initialize all parameter settings (panel
and main controller) to factory default.
Change the parameter setting
password.
Rotate the Command dial (
change numbers and places, and
press the Command dial (
) to save
the new password.
Description
Set the central heating supply
minimum temperature.
Setting range: 25°C – [MAX Set-
point – 20°C]
Default: 40°C
Set the central heating supply
maximum temperature.
Setting range: [MIN Set-point +
20°C] – 85°C
Default: 85°C
Set the temperature range to turn off
central heating.
Setting range : 0°C – 30°C
Default : 2°C
Set the temperature range to turn on
central heating.
Setting range : 1°C – 30°C
Default : 13°C
Item
5. Anti Fast Cycling
Time*
6. DHW Pre-Heat Set
Temp
7. DHW Burning Off
Diff
8. DHW Buring On
Diff
9. Burner Switching
Diff
) to
10. Freeze
protection
11. Boiler Pump
Delay
12. Low Pressure
13. Oil CMPS Rate
14. Service Notif
Time
Description
Set the anti-fast cycling time.
Setting range: 0 – 20 min
Default: 3 min
Set the DHW Pre-Heating Set
temperature.
Setting range: [DHW Set Temp +
10°C] – 80°C
Default: 75°C
Set the temperature range to turn off
Domestic Hot Water.
Stting range: 0°C – 30°C
Default: 0°C
Set the temperature range to turn on
Domestic Hot Water.
Setting range: 1°C – 30°C
Default: 20°C
Set the temperature range of SH
combustion switch.
Setting range: 5°C– 30°C
Default: 5°C
Set the pump freeze protection
temperature.
Setting range: 6°C – 10°C
Default: 10°C
The system freeze protection
Note
temperature is set based on
the pump freeze protection
temperature.
Set the boiler pump off delay time.
Setting range: 30 – 40 min
Default: 40 min
Set the low water pressure.
Setting range: 0.1 – 1.2 bar
Default: 0.4 bar
Set the oil consumption
compensation rate.
Setting range : -25% – 25%
Default : 0 %
Set the time for service notification.
Setting range: 30 – 3650 days (10
years)
It can be set in 10 day increments.
Default: 1820 days (5 years)