Navien LCB700-21RS Installation & Operation Manual page 57

Condensing blue flame oil-fired boiler
Table of Contents

Advertisement

System/Regular Models
Item
1. Operation State
Current Operation State
2. Heat Capacity
Heat capacity (Low or High)
3. CH Set Temp
Central heating set temperature (°C)
DHW indirect supply set
4. DHW Set Temp
temperature (°C)
5. Supply Temp
Heating supply temperature (°C)
6. Burner Temp
Burner housing sensor temperature (°C)
7. Outdoor Temp
Outdoor temperature (°C)
8. Water Press
Water pressure (bar)
Flame detector AD value
Flame On: 8bit AD values equal to or
9. Flame Value
lower than 70
Flame Off: 8bit AD values equal to
or higher than 175
10. Fan Target RPM
Set the fan speed (RPM)
11. Fan Current RPM
Current fan speed (RPM)
12. Fan Target APS
Set APS voltage (V)
13. Fan Current APS
Set the oil pump speed (RPM)
14. Oil Pump Target
Current oil pump speed (RPM)
RPM
15. Oil Pump Current
Oil Pump speed(RPM)
RPM
16. Exhaust Temp
Exhaust temperature (°C)
17. OTC ON/OFF
OTC Status (Enable/Disable)
18. K-Factor
K-Factor for the OTC
19. Model
Model type
20. Type
Boiler type
21. Oil
Oil type
22. Main F/W ver
Main firmware version
23. Panel F/W Ver
Panel firmware version
Combi Models
Item
1. Operation State
Current Operation State
2. Heat Capacity
Heat capacity (Low or High)
3. CH Set Temp
Central heating set temperature (°C)
4. DHW Set Temp
DHW set temperature(°C)
5. Supply Temp
Heating supply temperature (°C)
Description
Description
Item
6. Burner Temp
Burner housing sensor temperature (°C)
7. Outdoor Temp
Outdoor temperature (°C)
8. Water Press
Water pressure (bar)
8. Inlet Temp
Inlet temperature(°C)
9. DHW Temp
DHW temperature(°C)
10. Outlet2 Temp
DHW outlet2 temperature(°C)
11. Tank Temp
DHW pre-heat tank temperature(°C)
12. Water Press
Water pressure (bar)
Flame detector AD value
Flame On: 8bit AD values equal to or
13. Flame Value
lower than 70
Flame Off: 8bit AD values equal to
or higher than 175
14. Fan Target RPM
Set the fan speed (RPM)
15. Fan Current RPM
Current fan speed (RPM)
16. Fan Target APS
Set APS voltage (V)
17. Fan Current APS
Set the oil pump speed (RPM)
18. Oil Pump Target
Current oil pump speed (RPM)
RPM
19. Oil Pump Current
Oil Pump speed(RPM)
RPM
20. Exhaust Temp
Exhaust temperature (°C)
21. OTC ON/OFF
OTC Status (Enable/Disable)
22. K-Factor
K-Factor for the OTC
23. Model
Model type
24. Type
Boiler type
25. Oil
Oil type
26. Main F/W ver
Main firmware version
27. Panel F/W Ver
Panel firmware version
The fan motor controls APS, so the Fan Target RPM is
Note
only for your reference.
Description
Operating the Boiler
57