Specifications

Frequency Band:
RF Interface:
Modulation:
Frequency Source:
Configurations:
Latency:
Forward Error Correction:
PHYSICAL (Including radio, antenna & mount)
Weight:
Dimensions (WxHxD):
TRIBUTARY
Data Rate:
Standards Compliance:
Interface Options:
ELECTRICAL
Input Voltage:
ENVIRONMENTAL
Operating Temperature Range:
Altitude:
MANAGEMENT
REGULATORY
FCC:
ANTENNA
Web Site: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC's global sales office locations, please refer to our Web site.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
104680AE 5/08 Revision © 2008, 2007 ADC Telecommunications, Inc. All Rights Reserved
71 - 76 GHz; 81 - 86 GHz
FDD
DBPSK
Synthesizer
Non-Protected
Hot Standby
Repeater
Mesh
<10 usec
Reed Solomon
0.3 m /1 ft
0.6 m/2 ft
11.79 kg (26.0 lbs)
15.42 kg (34 lbs)
30 x 53 x 35.5 cm
40.6 x 68.5 x 66 cm
(12" x 21" x 14")
(16" x 27" x 26")
1250 Mbps full duplex (Gigabit Ethernet)
IEEE 802.3z
Fiber 850 nm Multi Mode, LC connector
Fiber 1310 nm, Single Mode, LC connector
1000Base-SX to 1000BaseT
-48 VDC (-40.5 to -57VDC)
-27° to +131°F (-33° to +55°C)
15,000 ft (4500 m)
Craft Interface Embedded web based (HTML) server
EMS SNMP
Voltmeter testpoints for Received Signal Strength
1.1310 RF MPE limits
Part 101
0.3 m/1ft
43.8 dBi
<0.9°BW
Fine adjust pole mount fitting 6.35 cm (2.5") to 11.43 cm(4.5") OD
0.6 m/2 ft
51 dBi
<0.4°BW

Advertisement