5.3. Error display
E1-00 : Disc cannot be detected
E1-01 : Tracking offset adjustment not possible
E1-02 : Focus offset adjustment not possible
E2-00 : Focus servo dropped during playback
E2-01 : Focus servo dropped during searching
E2-03 : Focus servo dropped during TOC reading
E2-06 : Focus servo dropped during manualsearch
E2-10 : Subcode can no longer be read during playback
E2-11 : Subcode can no longer be read during searching
E2-12 : Subcode can no longer be read during TOC reading
E2-14 : Subcode cannot be read during pause
E2-15 : Subcode cannot be read during manualsearch
E3-00 : TOC could not be read within speciied time
E3-01 : PVD/SVD analysis could not be completed within speciied time
E4-04 : Search time out
E4-05 : Error in communications with CD decoder
E5-00 : Inner switch not on
E6-00 : Inner switch not off
E9-00 : CD ucom error
E9-01 : Other error
z X-XX : Error cord
Number of heat run is displayed, when error occur.
• Press the " 9 " button while the error is displayed.
• No. heat runs is displayed for 5 seconds, the error display reappears.
z XXXX : Number of heart run repetitions.
The track no. and time when the error occurred is displayed.
• Press the " 8 " button while the error is displayed.
• The track no. and time when the error occurred is displayed for 5 seconds, then error display reappears.
z " _ C D _ _ _ x x Tr _ _ m m : s s "
z xx : Track Nunber of error occurred.
z mm:ss : Display Elapsed time in track which error occurred.