Perform installation or removal of the chassis or any module in a static-free environment. Proper
use of anti-static body straps and mats is strongly recommended.
Modules must be kept in anti-static packaging when not installed in the chassis.
Do not ship or store this product near strong electromagnetic, electrostatic, magnetic, or
radioactive fields.
Do not disassemble the chassis.

Selecting a Location

The 7010 controller, like other network and computing devices, requires the following "electronic-
friendly" environment:
Reliable power
Verify that your electrical outlet is compatible with the 7010 controller power supply.
Cool, non-condensing ventilation
For proper operation, the 7010 controller requires an environment with an ambient air
temperature between 0º C and 40º C (32º F and 104º F). Humidity must be kept at non-condensing
levels, between 5% and 95%.
Where a large number of electrical devices are working in the same area, additional air
conditioning or air circulation equipment may be required.
Ample space
For proper air circulation, leave at least 10 cm (4 inches) clearance all around the chassis.
Leave additional space in front and rear side of the chassis to access power cords, network cables,
and indicator LEDs.
Limited electromagnetic interference
For best operation, keep the 7010 controller and all cords and cables at least 0.7 meters (2 feet)
from fluorescent lighting fixtures, and 2 meters (6 feet) from photocopiers, radio transmitters,
electric generators, and other sources of strong electromagnetic interference.

Rack Mounting- Standard

This mounting option allows mounting the 7010 controller in a two-post 19-inch Telco rack.
Each 7010 controller should have its own mounting equipment. Do not place other networking equipment
!
directly on top of a mounted 7010 controller. Failure to do so can damage the device.
CAUTION

Required Tools and Equipment

The following tools and equipment are required for installing a 7010 controller:
Mounting Bracket (x2) (included in the kit): Do not use for table or shelf installation
Screws for mounting bracket (x8): M4 x 8 mm Phillips Flat Head Screws (included in the kit)
Screws for system rack mount (x4): M6 x 15 mm Phillips Pan Head Screws (included in the kit)
Suitable Screwdrivers for all screw types provided in the box (not included in the kit)
Some racks require screws that differ from those included with the 7010 controller. Ensure that you have the
correct screws before installing the 7010 controller.