Operating and display functions

Note
The functions described in this section are not available for all system configurations.
To call up the menu, press
2.12.1 CONTROL menu item
MENU → CONTROL
→ Zone
→ Name of zone
→ Heating → Mode:
→ Cooling → Mode:
→ Absence
→ Cooling for several days
→ Fixed value control, circuit 1
→ Heating → Mode:
→ Domestic hot water
0020287900_00 sensoCOMFORT Operating and installation instructions
twice.
Changing the name Zone 1, which was set at the factory
→ Manual
Uninterrupted retention of the desired temperature
→ Time-contr.
Weekly planner: Up to 12 time periods and desired temperatures can be set per day
The competent person sets how the heating installation behaves outside of the time period in the
Set-back mode: function.
In Set-back mode: means:
Eco: The heating is switched off outside of the time periods. Frost protection is activated.
Normal: The set-back temperature applies outside of the time periods.
Desired temperature: °C: Applies within the time periods
→ Off
Heating is switched off, domestic hot water continues to be available, frost protection is activated
→ Manual
Uninterrupted retention of the desired temperature
→ Time-contr.
Weekly planner: Up to 12 time periods can be set per day; cooling is switched off outside of the
time periods
Desired temperature: °C: Applies within the time periods
Cooling is switched off outside of the time periods
→ Off
Cooling is switched off, domestic hot water remains available
→ All: Applies only to any zones within the specified time period
→ Zone: Applies for the selected zone in the specified time period
Heating and domestic hot water mode is switched off, existing ventilation operates at the lowest
ventilation level, frost protection is activated
Cooling mode is activated in the specified time period, cooling mode and desired temperature are
used from the Cooling function
→ Manual
Uninterrupted retention of the Target flow temp., desired: °C that the competent person set.
→ Time-contr.
Weekly planner: Up to 12 time periods can be set per day
Within the time period, the Target flow temp., desired: °C is used.
Outside of the time periods, the Target flow temp., set-back: °C is used or the heating circuit is
switched off.
At a Target flow temp., set-back: °C = 0 °C, the frost protection can no longer be guaranteed.
The competent person sets both of these temperatures.
→ Off
The heating circuit is switched off.
Product description 2
→ Desired temperature: °C
→ Weekly planner
→ Set-back temperature: °C
→ Desired temperature: °C
→ Weekly planner
→ Desired temperature: °C
→ Weekly planner