Sony DVCAM DSR-PDX10 Service Manual page 191

Hide thumbs Also See for DVCAM DSR-PDX10:
Table of Contents

Advertisement

DSR-PDX10/PDX10P
19. AF Laser Axis Check
Subject
Measurement Point
Measuring Instrument
Specified Value
Note1: Background paper (J-2501-130-A) etc.. Perform this adjustment
in the dark place.
Note2: This adjustment should be carried out upon completion of "Auto
White Balance Standard Data Input".
Switch setting:
1) POWER ................................................................. MEMORY
2) FOCUS .................................................................. MANUAL
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
2
0
10
3
E
47
0A
4
0
10
5
6
23
6
6
5B
7
6
5C
A5
8
6
90
A9
9
6
91
10
6
92
11
6
93
12
6
01
13
6
01
14
15
Note3: When the specified value is not satisfied, rotate the screw as shown
in Fig. 6-1-23 and adjust the AF laser axis. (Horizontal direction
only)
Dark homogeneous subject
(1m from the front of the lens)(Note1)
Monitor TV screen
The total length of the hologram lines,
which are seen inside the inspection
frame, should be more than twice the
length of one hologram line.
The hologram lines can be seen at every
outside of the inspection frame.
Procedure
01
Set the data.
01
Set the data.
Set the data.
00
Set the data.
04
Set the data.
B6
Set the data.
Set the data.
Set the data.
02
Set the data.
67
Set the data.
46
Set the data.
79
Set the data, and press PAUSE
button.
78
Set the data, and press PAUSE
button.
Check that the total length of the
hologram lines (the whole or a
part), that are seen inside the
inspection frame, is more than
twice the length of one hologram
line. (Note3)
Check that the hologram lines can
be seen at every outside of the
inspection frame (the top, the
bottom, the left and the right).
(Note3)
Processing after Completing Adjustments:
Order Page Address Data
1
0
10
2
E
47
3
0
10
4
6
01
5
6
23
6
6
5B
7
6
5C
8
6
90
9
6
91
10
6
92
11
6
93
12
0
01
AF blind sheet
6-36
Procedure
01
Set the data.
00
Set the data.
00
Set the data.
00
Set the data, and press PAUSE
button.
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.
00
Set the data.
Inspection frame
Fig. 6-1-22.
To adjust the laser
hologram to the left
To adjust the laser
hologram to the right
Fig. 6-1-23.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvcam dsr-pdx10pDvcam rmt-811