3 Installation

3.1 Installation Preparation

3.1.1 Selection of Installation Location
(1) The unit must be installed where strong enough to withstand the weight of the
unit and fixed securely, otherwise the unit would topple or fall off.
(2) Install the air conditioner at a place where the inclination is less than 5°.
(3) Do not install the unit at a place with direct sunlight.
(4) Do not install where there is the danger of combustible gas leakage.
(5) Do not install the unit near heat source of heat, steam, or flammable gas.
Selection of Installation Location for Indoor Unit (Select a l ocation pursuant to
the following condition).
(1) Air i nlet a nd o utlet of t he indoor u nit s hould be a way f rom obs tacles t o
make sure the unit's air flow can reach the entire room. Do not install the
unit in a kitchen or a laundry.
(2) Select a l ocation t hat c an withstand 4 t imes t he unit weight without
increasing operating noise and vibration.
(3) The installation location must be level.
(4) The indoor piping length and wiring length should be within the allowable
range.
(5) Select a place that can easily drain condensate and connect to the drain
system of the air conditioner.
(6) If hoi sting s crew bolts ar e t o be us ed, c heck whether t he i nstallation
location i s s afe enou gh. I f not s afe, r einforce t he l ocation b efore
installation.
(7) Indoor u nit, p ower c ord, c onnecting wires and c ommunication c ords
should be at least 1m from television and radio. This is to prevent image
interference or noi se ( Even at a di stance of 1m , a v ery strong e lectric
wave may still generate noise).
N Series Floor Ceiling Type Unit