Operation - DeWalt DW082 Original Instructions Manual

Laser plumb bob
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 34
• Switch off the tool and remove the batteries as soon as the indicator
blinks.
Setting up the tool (fi g. C)
The tool has magnets (8) to hold it to steel fl oor track.
• Place the tool on a relatively smooth and level surface.
• Adjust the tool for a plumb application.
Adjusting the tool (fi g. C)
• To initiate the leveling procedure, switch on the tool. The plumb
orientation is correctly adjusted as long as the laser beams remain on.
• The laser beams start fl ashing to indicate that the tool has been set
up at a slope that is beyond the self-leveling range of 4°. Switch the
tool off, re-adjust the tool set-up within the self-leveling range and
switch the tool on again.
Aligning the laser dot (fi g. C)
• Align the laser dot of either one of the laser beams with the position
mark. Move the tool as required.

OPERATION

Instructions for use
WARNING: Always observe the safety instructions and
applicable regulations.
• Always mark the center of the laser dots.
• Make sure the tool has been set up securely.
• Extreme temperature changes cause movement of internal parts that
may affect the accuracy of the tool. Regularly check the accuracy
while using the tool under these circumstances.
• Although the tool corrects small out-of-level errors automatically, when
it is bumped, re-adjustment to balance or set-up may be required.
• If the tool has been dropped or has tipped over, have the laser head
calibrated by a qualifi ed repair agent.