Start Methods

Ice Making Mode Start Up
At power up in the ice making mode the electronic
control will monitor the following criteria:
If the evaporator temperature is colder than the
Harvest Termination temperature at start up the
controller will switch to the Lower state.
If there is an obstruction preventing the water plate
from closing the Plate Up switch at startup, the
controller will switch to the Lower state.
If the water plate is not in the up position at start up
and the evaporator temperature is warmer than the
Harvest Termination temperature, the controller will
switch to the Raise state.
Cleaning Mode Start Up
At power up in the wash mode the electronic control
will monitor the following criteria:
If there is an obstruction preventing the water plate
from closing the Plate Up switch at startup, the
controller will switch to the "Lower" state.
If the water plate is not in the up position at start up,
the controller will switch to the "Raise" state.