Installation
6. Slide the inner tube (T) of the hose through the slot
and into the fluid inlet port (P1) of the manifold.
Screw the hose ferrule (M) into the port.
WARNING
Electric Shock Hazard
To maintain grounding continuity, the con-
ductive hose layer (C) must be engaged in
the ferrule (M) when the nut (N) is tight-
ened. Failure to properly install the hose in
the fitting could result in an electric shock.
7. Screw the strain relief nut (N) onto the hose ferrule
(M). Tighten to about 55 in-lb (6.2 N•m). Pull back
on the hose to make sure it is secure.
8. Reinstall the shroud (2) and air cap (3).
9. Check the gun's electrical grounding (see page 19).
E
T
Fig. 8. Hose Connection at Isolated Fluid Supply
16
10. Connect the other end of the hose to the fluid outlet
C
J
of the isolated fluid supply. See F
WARNING
Electric Shock Hazard
To reduce the risk of electric shock, the
areas of the waterborne fluid hose that are
accessible to personnel during normal
operation must be covered by the outer
hose jacket (J). The portion of the inner
hose layer (T) not covered by the outer jacket must
be inside the voltage isolation system enclosure (E).
The conductive hose layer (C) must be grounded
through its connection to the isolation system's
grounded enclosure (E).