3.5

Diagnosing the SINAMICS configuration

Once the configuring for the SINAMICS S120 has been completed, the topology of the
DRIVE-CLiQ wiring can be checked in online mode and the drive moved using the
SINAMICS S120 control panel.
3.5.1

Checking the DRIVE-CLiQ wiring online

Procedure
To check the DRIVE-CliQ wiring online, follow these steps:
1. Set S7T Config to online mode.
2. Open the "S120_CU320" folder.
3. Select the "Topology" command.
Result
The "Topology" dialog will open.
By making a comparison of the planned and the actual topology in the display windows,
any incorrect wiring of the DRIVE-CLiQ connections can be determined quickly.
The display topology views have the following meaning:
Corrections in the wiring can be made by means of the hardware by replugging the
DRIVE-CLiQ connections or in the "Project set" window by dragging the components to the
correct DRIVE-CLiQ connection.
Connection of the SINAMICS S120 to the Technology CPU
Product Information, 09/2011, A5E00480378-04
Topology view
Planned project
Planned
Actual
3.5 Diagnosing the SINAMICS configuration
Topology of the DRIVE-CLiQ components programmed offline in
S7T Config.
Topology of the wiring of the DRIVE-CLiQ components loaded
online into the drive.
Real wiring of the DRIVE-CLiQ drive components.
Commissioning
Meaning